M5400 -EX Front Panel Features
Power Button
Press and hold for 2 sec- onds to turn Outlet Banks 3, 4 and 5 ON or OFF. This switch is bypassed if the rear panel DC Trigger input is being used.
Power LEDs
Indicates the status of the rear panel outlets. LEDs for each outlet bank will be lit when the outlets are turned ON. They will flash during the start- up and shutdown process.
Wiring OK LED
Normally On. Indicates that the wall outlet is properly grounded and Line/Neutral polarity is correct.
Meter Dimmer
Pushbutton control for meter LED brightness. Cycles between Off, Low, Medium and High.
Voltmeter
Digital LED voltmeter indi- cates incoming line voltages between
Ammeter
Shows the actual current draw
Convenience
Outlet
Provides a quick con- venient way to plug in components such as camcorders and video game systems.
VOLTSAMPS
BANK 1 | BANK 2 | BANK 3 | BANK 4 | BANK 5 | WIRING |
ALWAYS ON | ALWAYS ON | ON | ON | ON | OK |
|
|
|
|
| METER |
POWER AND FILTRATION |
|
| LIGHTS |
Home Theater Power Conditioner
Unsafe Voltage Indicator
Normally Off. Flashes to indicate that the incom- ing line voltage is unsafe and the unit has discon- nected the power to protect your equipment.
M5400 -EX Back Panel Connection Features
Circuit Breaker
Automatically opens when the current load is greater than 15 Amps. Push to reset.
Outlet Banks 3 & 4
Two switched outlets per bank. ON/OFF status is controlled by the front panel Power Button or the DC Trigger input. They will turn on immediately and turn off after 10 seconds. EMI/RFI noise filtration is pro- vided by the Isolation Transformer in con- junction with a
Outlet Banks 1 & 2
Two always on outlets per bank. Power will only be turned off under a fault condition. (See specifica- tions for
Satellite TV
Coax Jacks
Bidirectional protection cir- cuit optimized for satellite TV signal lines. Do not use for cable TV
Cable TV Coax Jacks
Bidirectional protection cir- cuit optimized for cable TV,
15 AMP CIRCUIT | BANK 5 |
BREAKER |
|
| RECEIVER |
GROUND |
|
LUG |
|
| DELAY ON |
| SUB / AMP |
MAIN POWER | HIGH CURRENT |
120 VAC/15A |
|
BANK 4
SWITCHED
BANK 3
CD
DVD
SWITCHED
BANK 2
DIGITAL RADIODVR
ALWAYS ON
BANK 1
HD CABLE / SATHDTV / MONITOR
ALWAYS ON
|
| SATELLITE |
|
|
| CATV / ANT |
| |
| SATELLITE 1 |
|
| SATELLITE 2 |
| CATV / ANT 1 |
| CATV / ANT 2 |
VOLTAGE | HIGH |
|
| LAN |
| PHONE | ||
SENSE TRIGGER | CURRENT | ISOLATED | LINE | EQUIP. | LINE | EQUIP. | ||
INPUT | OUTPUT | OUTLETS | OUTLETS |
|
|
|
| |
|
|
|
| |||||
|
|
|
|
|
| |||
|
| DELAY | DELAY |
|
|
|
| |
|
| ON | 5 | ON 10 |
|
|
|
|
|
|
| SEC. | SEC. |
|
|
|
|
Main Power
Must be plugged into a properly wired & ground- ed
Ground Lug
Provides a common grounding point for equipment with sep- arate ground leads.
Outlet Bank 5
Two switched, high current outlets controlled by the front panel Power Button or the DC Trigger input. Bank 5 has a 5 second turn on delay and turns off immediately. The High Current outlets pro- vide power from a low impedance noise filtration circuit that does not limit the current to your equipment. Its output is noise isolated from all of the other outlet banks.
Voltage Sense
Trigger Input
3.5mm (1/8”)
Voltage Sense
Trigger Output
3.5mm (1/8”)
High Current Outlets
Delay Switch For
Outlet Bank 5
Allows the outlet bank to be set as “Always ON” or with a 5 second
Switched Outlets Delay Switch For Outlet Banks 3 & 4
Allows the outlet banks to be set as “Always ON” or with a 5 second turn- off delay
LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines. Incoming LAN line MUST be plugged into the LINE jack. Patch cord to the equipment MUST be plugged into the EQUIP jacks.
Phone Jacks
Protection circuits for standard telephone or pay-
Note to CATV Installers:
This reminder is provided to call attention to Article