Speco Technologies P-30FACC instruction manual

Page 6

8 ~ 11) Zone 1~4 output terminals. In addition to the normal 70V and 25V line outputs, there are four groups of 70V or 25V (internally selected, see page 10) line terminals for 4 zones which can be selected using the push buttons on the front panel.

12)AC input cable receptacle . AC inlet with three pin socket for use of either 115VAC or 230VAC selected by slide switch on rear panel (see page 4). The amplifier is factory set at 115VAC main voltage. (230VAC operation requires AC plug adaptor.)

13)AC 115V/230V selector switch (Beneath small metal cover, see drawing of rear panels on page 4). Allows for selection of either 115VAC or 230VAC operation. For operating on 230VAC main voltage, remove the small metal cover with a screw driver and slide the voltage select switch’s actuator from 115VAC(factory set, left side) to 230VAC(right side), then re-mount the small metal cover with the 230VAC sticker showing on back of small metal cover and tighten screws.

14)AC fuse holder. Line fuse for the amplifiers:

P–30FACC and P–30FACD - 2A for 115VAC

-1A for 230VAC

P–60FACC and P–60FACD - 3A for 115VAC

-1.6A for 230VAC

15)LINE output RCA jacks. This booster output supplies the input signal to an additional power amplifier. This signal is after tone control and master volume control. In this fashion, very large systems requiring more power can be accommodated.

16)AUX input RCA jacks. High impedance input available with parallel RCA jacks (for stereo accessories combined for mono.)

17)MIC-4 (XLR connector) input. Accepts a balanced low impedance microphone signal

with an XLR connector.

18)MIC-3 (XLR connector) input. Accepts a balanced low impedance microphone signal with an XLR connector.

19)MOH output level control. Controls volume of MOH output. (Music on hold)

20)MIC-1 VOX on/off switch. Allows for disabling of MIC-1 input VOX muting of the MIC-2~4 and AUX input during paging. This allows for multiple MIC paging/operation.

21)MIC-2 (XLR connector) input. Accepts a balanced low impedance microphone signal with an XLR connector.

22)TEL/PAGING input level control. Controls audio level of telephone input.

23)MIC-1 (XLR connector) input. Accepts a balanced low impedance microphone signal with an XLR connector.

Note: Screw terminal designations: G-GND, HOT-Signal positive, COM-Signal negative/common.

6

Image 6
Contents Instruction Manual Important Safety Instructions Controls and Connections Front PanelRear Panel Facc FacdTEL / Paging balanced input terminals Page Cassette Player Unit CD Player UnitCD Player Operation Cassette Player OperationFast Wind Inserting a CassetteRemoving the Cassette Direction ChangeOvercoming Ground Loop Problems Speaker ConnectionHOW to Connect Line Matching Transformers in Parallel Speaker ImpedancesPhantom Power Jumper Positioning Cable RequirementsDetermining Your Amplifier Needs For Sound Systems Technical Specifications +12 123#45