Toshiba PWU001Z-1 operation manual Comparing function comp, ・・・

Page 10

E6580724

4.3. Comparing function “comp”

This function enables the operator to compare data stored in two memories that are selected from among four memories of the parameter writer's memories A, B and C and the inverter's memory as well as to search a parameter which is different in the setting value from others.

The comparing function cannot be used for editing data because it is provided for searching parameters which are different in setting values from others.

Use the “Remote keypad” function described in Section 4.6 to edit data. Operating procedure

 

 

Key

LED indication

Key operation and description

 

 

 

 

 

“chc ”→“init”→

When the parameter writer is turned on as it is connected with the inverter,

 

 

 

 

 

“chc” appears on the display first and then “init” appears to indicate that

 

 

 

 

 

 

 

 

 

 

 

“c0py”

the power supply is being initialized. Lastly, the display shows “copy”.

・・・

“c0py”→“c0mp”

Selecting a desired function

Select to “comp” (comparing function) with the SFT key.

 

 

SFT

 

 

 

 

Each time the SFT key is pressed, indication on the display changes from

 

 

 

"copy' to “comp” (comparing function). "prot " (memory protecting

 

 

 

 

 

 

function), “clr” (memory initializing function) and to "copy" again in this

 

 

 

 

 

 

order.

 

 

 

 

 

“c0mp”→“in”

Entering the selected function

 

 

ENT

After selecting "comp" with the SFT key, press the ENT key and "in"

 

 

 

 

 

 

(selecting inverter memory) appears on the display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“in”→“a”→“b”

Selecting a memory to compare its data with another

 

 

SFT

Each time the SFT key is pressed, indication on the display changes from

 

 

 

 

 

→“c”→“in”

''in” (selecting inverter memory) to "a'' (selecting memory A), “b”' (Selecting

 

 

 

memory B), “c” (selecting memory C) and to “in" again in this order.

 

 

 

 

 

 

Select the copy destination area.

 

 

 

 

 

“in”→“in a”

Entering the memory to compare its data with another

 

 

ENT

After selecting ''in '' (selecting inverter memory, for example) with the SFT

 

 

 

 

 

 

key, press the ENT key and ”in a" appears on the display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“in a”→“in b”

Selecting a memory to compare its data with that of the previously selected

 

 

 

 

 

memory

 

 

SFT

→“in c”→“in a” Each time the SFT key is pressed, indication on the display changes from “in

 

 

(“a in”→“a b”

a" (comparing data between inverter memory and memory A) to “in b”

 

 

 

 

 

 

 

(comparing data between inverter memory and memory B),”in c”

 

 

 

 

 

→“a c”→“a in”)

(comparing data between inverter memory to memory C), and to “in a”

 

 

 

 

 

 

again in this order.

 

 

 

 

 

 

If the memory A is selected as the memory storing the original data, indications

 

 

 

 

 

 

differently appear as shown in parentheses.

 

 

 

 

 

“in a”

Entering the selected memory to compare its data with the original

 

 

ENT

After selecting “in a” (selecting memory A to compare its data with that of

 

 

 

 

 

 

the inverter's memory for example) with the SFT key, press the ENT key and

 

 

 

 

 

 

the parameter writer starts comparing data of the two memories with each

 

 

 

 

 

 

other.

 

 

 

 

 

“f000”→“f002 ”

Executing comparing data (searching different parameters)

 

 

 

 

 

After confirming that “f000” is appearing on the display, execute comparison

 

 

 

 

 

(If no parameter different

 

 

 

 

 

of data in order of communication number (refer to the Table of communication

 

 

 

 

 

from the other is

 

 

ENT

numbers.). When the parameter writer searches a parameter different from the

 

 

searched,

 

 

 

 

 

other, it discontinues comparing operation and shows the parameter's

 

 

 

 

 

the display shows

 

 

 

 

 

communication number in blinking numerals.

 

 

 

 

 

“end”)

Press the ENT again to continue the comparing operation.

 

 

 

 

 

“end”→“__

Comparing is complete

 

 

 

 

 

With completion of data comparison, “end” appears on the display first and

 

 

 

 

 

 

 

 

 

 

 

 

then “_ _” of a check data (check sum of the original data) appears. Value of

 

 

 

 

 

 

 

 

 

 

 

 

the check data changes depending on the condition of the original data.

 

 

 

 

 

__”→“comp”

Ending comparing

 

 

ENT

Press the ENT key and indication on the display returns to “comp”.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the ESC key is pressed, the parameter writer returns to the status one before.

- 9 -

Image 10
Contents Table of Contents PWU001Z-1Preface PWU 001 ZCarefully read the following notes Safety precautions Handling in generalE6580724 Overview Memory To InverterNames and functions of main parts VEC ECN PRG Parameter Writer Remote KeypadConnection and start-up Functions in detail Copying function copySimply copying function RUNComparing function comp ・・・Table of communication numbers Memory protection function prot -Selecting a desired function -Memory initializing function clr Function to serve as remote keypadIndications on display LED indication DescriptionSpecifications Resetting functionWarranty

PWU001Z-1 specifications

The Toshiba PWU001Z-1 is a cutting-edge device that epitomizes Toshiba's commitment to innovation and quality in technology. Tailored for both residential and commercial uses, this portable air conditioning unit offers an effective and efficient solution for climate control, allowing users to enjoy a comfortable environment regardless of external conditions.

One of the standout features of the Toshiba PWU001Z-1 is its powerful cooling capacity. With a robust BTU rating, this unit can rapidly cool medium to large spaces, making it an ideal choice for living rooms, offices, and other areas that require immediate climate adjustment. In addition to cooling, the PWU001Z-1 also offers a heating function, providing year-round comfort by seamlessly transitioning from cooling to heating mode as needed.

The unit incorporates advanced inverter technology, which enhances energy efficiency by optimizing compressor speed. This not only helps in reducing electricity bills but also contributes positively to environmental sustainability. The inverter mechanism ensures that the temperature remains consistent by dynamically adjusting the cooling output based on the set temperature, eliminating the need for frequent on-and-off cycles that can wear out the system and lead to temperature fluctuations.

Another notable feature of the Toshiba PWU001Z-1 is its user-friendly interface. Equipped with a digital display and remote control, users can easily adjust settings from a distance. The intuitive control system includes programmable timers and multiple modes, such as "Eco" mode, which further ensures energy savings while maintaining comfort levels.

In terms of air quality, the PWU001Z-1 is designed with a multi-stage filtration system that captures dust, allergens, and other airborne particles. This improves indoor air quality, making it suitable for individuals with allergies or respiratory conditions. The quiet operation of the unit adds to its appeal, as it allows for a serene environment without disruptive noise levels.

Durability is another hallmark of the Toshiba PWU001Z-1. Built with high-quality materials and engineered for longevity, this unit promises reliable performance over time. Its sleek and modern design not only enhances aesthetic appeal but also ensures that it seamlessly fits into various interior styles.

In summary, the Toshiba PWU001Z-1 stands out for its powerful cooling and heating capabilities, energy-efficient inverter technology, user-friendly controls, advanced air filtration system, and durable construction. This unit represents the latest advancements in portable air conditioning, making it a worthwhile investment for anyone seeking to enhance their indoor climate control solutions.