Toshiba PWU001Z-1 operation manual Functions in detail, Copying function copy

Page 8

E6580724

4. Functions in detail

4.1. Copying function “copy”

Data stored in a memory can be copied to another memory which memories are selected from among four memories that are the inverter's memory, memories A, B and C of the parameter writer.

Note: To copy data to the inverter’s memory, do it when the inverter is stopped. If you copy data to the inverter while the inverter is running, some of the parameters fail to be copied. Furthermore, make sure to check the copied data by executing data comparison (comp) between the source and the

destination memories after the copying operation.

Operating procedure

Key

LED indication

Key operation and description

 

“chc ”→“init”

When the parameter writer is turned on as it is connected with the inverter,

 

"chc" appears on the display first and then "init " appears to indicate that

 

 

 

→“c0py”

the power supply is being initialized. Lastly, the display shows " copy ".

 

“c0py”→“c0mp”

Selecting a desired function

SFT

Select “copy” (copying function) with the SFT key.

 

→“pr0t”→“clr”

Each time the SFT key is pressed. indication on the display changes from

→“c0py”

“copy” to “comp” (comparing function),”prot" (memory protecting

 

function). “clr” (memory initializing function) and to..”copy” again in this

 

 

order.

 

“c0py”→“in”

Entering the selected function

ENT

After selecting "copy" with the SFT key, press the ENT key and in"

 

 

(selecting inverter memory) appears on the display.

 

 

 

 

 

SFT

“in”→“a”→“b”

Selecting a memory to copy its data

Select a memory to copy its data with the SFT key.

→“c”→“in”

Each time the SFT key is pressed, indication on the display changes from “in”

 

 

(Selecting inverter memory) to “a" (selecting memory A), “b" (Selecting

 

 

memory B), "c" (selecting memory C)" and to ''in" again in this order.

 

“in”→“in-a”

Entering the memory to copy its data

ENT

After selecting "in " (selecting inverter memory, by way of example) with the

 

 

SFT key, press the ENT key and "in-a” appears on the display.

 

 

 

 

“in-a”→“in-b”

Selecting a memory to transcribe copied data

 

Select a memory to transcribe copied data with the SFT key.

SFT

 

→“in-c”→“in-a”

Each time the SFT key is pressed, indication on the display changes from "in-

(“a-in”→“a-b”

a” (copying data from inverter memory to memory A) to "in-b" (copying data

from inverter memory to memory B), “in-c” (copying data from inverter

 

→“a-c”→“a-in”)

memory to memory C), and to “in-a" again in this order.

 

If the memory A is selected as the origin to copy data. indications differently

 

 

 

 

appear as shown in parentheses.

 

“in-a”→“f000”

Entering the selected memory to transcribe copied data

ENT

After selecting “in-a” (selecting memory A, by way of example) with the SFT

 

f

key, press the ENT key and the display shows "f_ _ _” that is the

 

→“ _ _ _”

communication number of the parameter being copied.

 

 

 

“end”→“_ _”

Copying is complete

 

With completion of data copy, “end” appears on the display first and then “_ _”

 

 

 

(two digits)

of a check data (check sum of the origin of copied data) appears. Value of the

 

 

check data changes depending on the condition of the original data.

 

“__”→“c0py”

Ending copying

ENT

Press the ENT key and indication on the display returns to “copy".

 

 

Make sure to check the data with data comparison function (comp) after this

 

 

operation.

If the ESC key is pressed, the parameter writer returns to the status one before.

When the memory protection function is actuated, the parameter writer inhibits to copy data with "prot'' appearing on the display.

If there is no data in the memory A of the parameter writer though it is selected as the origin to copy data, the display shows ''err.a'' and copying data is of course impossible. (When the memory B is selected in the same condition, ''err.b'' appears on the display. When the memory C is selected in the same condition, ''err.c'' appears on the display.)

- 7 -

Image 8
Contents Table of Contents PWU001Z-1Preface PWU 001 ZCarefully read the following notes Safety precautions Handling in generalE6580724 Overview Memory To InverterNames and functions of main parts VEC ECN PRG Parameter Writer Remote KeypadConnection and start-up Functions in detail Copying function copySimply copying function RUNComparing function comp ・・・Table of communication numbers Memory protection function prot -Selecting a desired function -Memory initializing function clr Function to serve as remote keypadIndications on display LED indication DescriptionWarranty Resetting functionSpecifications

PWU001Z-1 specifications

The Toshiba PWU001Z-1 is a cutting-edge device that epitomizes Toshiba's commitment to innovation and quality in technology. Tailored for both residential and commercial uses, this portable air conditioning unit offers an effective and efficient solution for climate control, allowing users to enjoy a comfortable environment regardless of external conditions.

One of the standout features of the Toshiba PWU001Z-1 is its powerful cooling capacity. With a robust BTU rating, this unit can rapidly cool medium to large spaces, making it an ideal choice for living rooms, offices, and other areas that require immediate climate adjustment. In addition to cooling, the PWU001Z-1 also offers a heating function, providing year-round comfort by seamlessly transitioning from cooling to heating mode as needed.

The unit incorporates advanced inverter technology, which enhances energy efficiency by optimizing compressor speed. This not only helps in reducing electricity bills but also contributes positively to environmental sustainability. The inverter mechanism ensures that the temperature remains consistent by dynamically adjusting the cooling output based on the set temperature, eliminating the need for frequent on-and-off cycles that can wear out the system and lead to temperature fluctuations.

Another notable feature of the Toshiba PWU001Z-1 is its user-friendly interface. Equipped with a digital display and remote control, users can easily adjust settings from a distance. The intuitive control system includes programmable timers and multiple modes, such as "Eco" mode, which further ensures energy savings while maintaining comfort levels.

In terms of air quality, the PWU001Z-1 is designed with a multi-stage filtration system that captures dust, allergens, and other airborne particles. This improves indoor air quality, making it suitable for individuals with allergies or respiratory conditions. The quiet operation of the unit adds to its appeal, as it allows for a serene environment without disruptive noise levels.

Durability is another hallmark of the Toshiba PWU001Z-1. Built with high-quality materials and engineered for longevity, this unit promises reliable performance over time. Its sleek and modern design not only enhances aesthetic appeal but also ensures that it seamlessly fits into various interior styles.

In summary, the Toshiba PWU001Z-1 stands out for its powerful cooling and heating capabilities, energy-efficient inverter technology, user-friendly controls, advanced air filtration system, and durable construction. This unit represents the latest advancements in portable air conditioning, making it a worthwhile investment for anyone seeking to enhance their indoor climate control solutions.