© Siemens AG 2013
Technical specifications SIMATIC IPC427D
General features |
|
Design | • DIN rail mounting |
| • Wall mounting |
| • Portrait mounting |
Processor | • Intel Celeron 827E 1.4 GHz, |
| 1,5 MB SLC |
| • Intel Core |
| 3 MB SLC |
| • Intel Core |
| 4 MB SLC |
Main memory | Memory modules without ECC: |
| • 1 GB |
| • 2 GB |
| • 4 GB |
| • 8 GB |
| Memory modules with ECC: |
| • 4 GByte |
| • 8 GByte |
Free slots for expansions | Up to 2 x PCIe cards, depending |
| on enclosure design (1 x PCIe x4 |
| and 1 x PCIe x1) |
Graphics | • Integrated Intel HD2000 or |
| HD4000 |
| • DVI resolution of 640 x 480 pix- |
| els up to 1920 x 1200 pixels |
| • Maximum display port resolution |
| 1920 x 1200 pixels |
| • Graphics memory is occupied in |
| the main memory |
| (UMA dynamic) |
Power supply | 24 V DC |
Rated conditions | |
Operating systems |
|
Available | • Without |
| • Windows Embedded Standard 7 |
| • Windows 7 Ultimate MUI |
• Linux | |
| • QNX |
| • VxWorks |
Drives and storage media |
|
CFast card | • 2 GB optional or |
| • 4 GB optional or |
| • 8 GB optional or |
| • 16 GB optional |
Hard disk | 2.5", ≥ 250 GB, SATA |
2.5"; ≥ 80 GB Standard, | |
| ≥ 50 GB |
|
|
USB stick | External, can be connected via |
| USB port |
Interfaces |
|
Serial | • COM1 (RS 232) |
| • COM2 (RS 232); optional |
Graphics | • |
| VGA |
| • DPP++: Display port, DVI via |
| |
USB | 4 x USB 3.0, max. 2 |
| at the same time, downward- |
| compatible with USB 2.0/1.1 |
Ethernet | • 2 x RJ45 (10/100/1000 MBit/s) |
| |
| • 1 x RJ45 (10/100/1000 MBit/s) |
| with PROFINET versions |
PROFIBUS DP | 12 Mbit/s (isolated, compatible |
| with CP 5622), optional |
PROFINET | 3 x RJ45 (10/100 Mbit/s), |
| CP 1616 onboard, optional |
CAN interface | Optional |
Keyboard, mouse | Connection via USB port |
Advanced device functions |
|
Temperature | • When permitted operating tem- |
| perature range is exceeded |
| • Warnings can be analyzed by |
| application program (local, via |
| LAN) |
Watchdog | • Monitoring function for program |
| execution |
| • Restart can be parameterized in |
| the event of a fault |
| • Warnings can be analyzed by |
| application program (local, via |
| LAN) |
LED display | 4 LEDs for displaying system |
| status, 3 of these can be |
| programmed by the user |
Up to 15 ms buffer time at full | |
| load |
Buffer memory | 512 KB MRAM 1 optional |
|
|
All rights reserved | SIMATIC IPC427D | 2/4 |
© Copyright Siemens AG 2013 |
|
|