LED | State | Description |
|
|
|
| Off | The port is not operating at 100 Mbps.* |
* When the 1000M and 100M LEDs are both off, the port is operating at 10 Mbps.
DIP Switch Settings
The DIP switches as described in the following table allow you to set the operating mode of the line card. For information about the operating modes as well as Smart MissingLink, MissingLink, and OAM, refer to the relevant management software user’s guide.
Operating Mode | DIP 1 | DIP 2 | DIP 3 | DIP 4 |
|
|
|
|
|
|
|
|
|
|
Link Test (default) | OFF | OFF | OFF | X |
|
|
|
|
|
Smart MissingLink (SML) | OFF | ON | ON | X |
|
|
|
|
|
MissingLink (ML) | OFF | OFF | ON | X |
|
|
|
|
|
OAM Bypass | ON | OFF | OFF | X |
|
|
|
|
|
OAM Visible | ON | ON | OFF | X |
|
|
|
|
|
“X” means that the DIP switch position can be ON or OFF.
Twisted Pair Port Pinouts
The pinouts for the
1 | 8 | 8 |
| 1 |
The following table lists the
| MDI Mode |
|
|
| |||
|
|
|
|
|
|
|
|
Pin |
|
| Signal |
| Pin |
| Signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| TX+ |
| 1 |
|
| RX+ |
|
|
|
|
|
|
|
|
2 |
| TX- |
| 2 |
|
| RX- |
|
|
|
|
|
|
|
|
3 |
| RX+ |
| 3 |
|
| TX+ |
|
|
|
|
|
|
|
|
6 |
| RX- |
| 6 |
|
| TX- |
|
|
|
|
|
|
|
|
Warranty Information
The
Specifications
Physical, Environmental, and Electrical Ratings
Dimensions (H x W x L) | (2.2 cm x 7.3 cm x 13.0 cm) |
| .78 in. x 2.89 in. x 5.1 in. |
Operating Temperature | 0° C to 40° C (32° F to 104° F) |
Storage Temperature | |
Operating Relative Humidity | 5% to 90% |
Storage Relative Humidity | 5% to 95% |
Operating Altitude Range | Up to 3,048 m (10,000 ft.) |
Predicted MTBF (Telcordia SR332) | 880,000 hours |
Power Consumption | 6.5 Watts maximum |
4
Electrical Safety and Emissions Statements
This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Emissions | FCC Class A, EN55022 Class A, VCCI Class A, |
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950 (cULus), EN60950 (TUV), CSA22.2 No. 950
5
Copyright © 2008 Allied Telesis, Inc. All rights reserved.
6