Altinex PNP200 manual Operation, LOCK, RELEASE, Status Control Pins

Page 11

ACCESSORIES

unit. Do not keep the cord too tight or too loose (See Diagram 4, page 6).

Figure 4: Mounting Brackets

Step 7. Make that the provided ground wire assembly is secured to the threaded nut located on the bottom of the housing of the PNP200 with a star-washer and a 4-40 screw as shown in Diagram 4, page 6.

Step 8.Attach the other end of the ground wire assembly to a Protective Earth Ground with provided 6-32 screw and star-washer.

Step 9.Connect the appropriate cables with the correct input connectors. There are two RCA connectors on each side of the PNP200. The black connectors are known as audio left, whereas the red connectors are called audio right. On either side of the unit, there is also a RCA video connector, which is yellow in color. The network connection is red; In addition, the telephone or data connection is gray.

Step 10. Once you have applied power and connected the proper cables on the bottom of the unit, you may raise the unit. To raise the PNP200 into position, press the top of the unit.

Step 11. To lower the unit, push on the top of the PNP200 until it fits into place. When the 9V DC adapter is plugged in, 9 volts must be applied. Once the 9 volts have been applied, the release top connection will be engaged. This mechanism allows the unit to lock into place, and then pop up when pressure is put on the top of the unit.

CONGRATULATIONS! YOU ARE DONE. ENJOY YOUR Pop `N Plug™ Interconnect Box .

If you experience any problems, please call

1-800-258-4623 or 1-714-990-2300 for

international calls.

OPERATION

7

7.1 LOCK, RELEASE, STATUS CONTROL PINS

To lock the position of the PNP200, connect the LOCK pin of the terminal block to GND. Note: the power supply is rated at 9V, but since the current demand of the PNP200 is low, it will reach 12 volts at the terminal block. If a regulated power supply is used, it should be a 12-volt power supply. A regulated power supply is when the power supply is at 12 volts, and when the power supply is at 9 volts, it is known as unregulated.

To release the top connector assembly, connect the RELEASE pin of the terminal block to GND.

To determine the status of the PNP200, examine the STATUS pin. The status pin should be a TTL digital level only. When the PNP200 is in an up position 5 volts is present, whereas 0 volts represents the down position.

7.2HOW TO RELEASE AND REPLACE THE GAS SPRING

To replace the spring, push up, and turn the knob in the center on the bottom of the PNP200 by 90 degrees, thereby releasing the gas spring.

Unscrew the knob, and then unscrew the gas spring itself from the PNP200. Replace the gas spring with a new one by screwing it in, and then replacing the knob.

Re-engage the new gas spring by pushing up, and turning the knob by 90 degrees. After you have finished this step, you have completed the installation.

10

10

Image 11
Contents PNP200 P Introduction Table of ContentsGeneral Precautions / Safety WarningsInstallation CleaningFEATURES/DESCRIPTION General About Your PNP200 Technical SpecificationsPNP200 Dimensions Diagram 2 Back View of PNP200 Application Diagram Diagram 4 Final Installation Diagram 5 Table Cutout Requirements Gas Spring InstallationOperation LOCK, RELEASE, Status Control PinsHOW to Release and Replace the GAS Spring VGA Male to Female HD- 15 High Resolution Cable AccessoriesPower Cables VGA Male to Male HD-15 High Resolution CableReturn Policy Troubleshooting GuideLimited Warranty Altinex Policy