ADTRAN 1500 specifications Maintenance, Specifications, Warranty and Customer Service

Page 6

Front Panel LEDs

The Total Access 1500 Dual 4-Wire TO has two front panel LEDs that provide status information for each interface. See Table 4 for LED indications.

4. TEST FEATURES Initiated Tests

The Dual 4-Wire TO supports a Digital Network Loopback and 1004 Hz Tone Tests for each port to support circuit turnup and maintenance efforts. These tests are initiated from the Total Access Site Manager or the Total Access 1500 Local Craft Port on the SCU, and are initiated on an individual port basis.

Digital Network Loopback Test

The Digital Network Loopback provides a loopback path for the DS0 data from the network. Received data of the selected port is latched in on the appropriate receive time slot on the receive bus, and then placed on the transmit bus in the appropriate port’s transmit time slot.

1004 Hz Tone Test

The 1004 Hz Tone Test generates a 1004 Hz @

0 dBm Digital Reference Signal (DRS) tone, which is used to send DRS signal to the loop, to the network, or to both simultaneously.

5. MAINTENANCE

The Total Access 1500 Dual 4-Wire TO requires no routine maintenance for normal operation.

ADTRAN does not recommend that repairs be performed in the field. Repair services may be obtained by returning the defective unit to ADTRAN. Refer to Warranty and Customer Service section for further information.

6. SPECIFICATIONS

Specifications for the Dual 4-Wire TO are detailed in

Table 5.

7. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within ten

(10)years from the date of shipment if it does not meet its published specifications or fails while in service. Refer to ADTRAN U.S. and Canada Carrier Networks Equipment Warranty, Document 60000087-10.

Contact Customer and Product Services (CAPS) prior to returning equipment to ADTRAN.

For service, CAPS requests, or further information, contact one of the following numbers:

ADTRAN Sales

Pricing/Availability (800) 827-0807

ADTRAN Technical Support

Pre-sales Applications/Post-sales Technical Assistance (800) 726-8663

Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST

Emergency hours: 7 days/week, 24 hours/day

ADTRAN Repair/CAPS

Return for Repair/Upgrade (256) 963-8722

Repair and Return Address

ADTRAN, Inc. CAPS Department

901 Explorer Boulevard Huntsville, Alabama 35806-2807

 

 

Table 4. Front Panel LEDs

 

 

 

Label

Condition

Description

 

 

 

1

Green

Port 1 is operating normally

 

Yellow

Port 1 is in a menu controlled test

 

Red

Port 1 failure has been detected

 

 

 

2

Green

Port 2 is operating normally

 

Yellow

Port 2 is in a menu controlled test

 

Red

Port 2 failure has been detected

 

 

 

6

Section 61180212L2-5, Issue 1

61180212L2-5A

Image 6
Contents Contents TablesGeneral Compliance Codes InstallationCompliance Time Slot AssignmentsTime Slot and Wiring Interconnect Dual T1 Quad T1 D4 Quad T1 D1DD14 Provisioning Password and User IDDual 4-Wire to Options Menu NavigationMaintenance SpecificationsWarranty and Customer Service Specifications PerformanceL2-5, Issue