2. INSTALLATION

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Remove the Total Access 1500 Dual 4-Wire TO from the carton and visually ensure that damage has not occurred during shipping or handling. If damage has occurred, file a claim with the carrier, then contact ADTRAN. Refer to Warranty and Customer Service section of this practice.

The Dual 4-Wire TO inserts into any Access Module slot (1 through 24) of the Total Access 1500 chassis.

To install the Dual 4-Wire TO access module, perform the following steps:

1.Hold the unit by the front panel while supporting the bottom side.

2.Align the card edges to the guide grooved for the designated slot.

3.Insert the card until the edge connector seats firmly into the backplane.

4.Push the ejector in place to ensure the unit is fully seated.

Compliance

Table 1 shows the Compliance Codes for the Dual

4-Wire TO. The Dual 4-Wire TO complies with UL 1950, third edition. It is intended for installation in restricted access locations only and in equipment with a Type “B” or “E” installation code.

Table 1. Compliance Codes

Code

Input

Output

 

 

 

Power Code (PC)

C

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

 

 

 

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

1.This device may not cause harmful interference.

2.This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.

Time Slot Assignments

For time slot assignments in the Dual T1 mode and in the Quad T1 mode, refer to Table 2.

The Total Access 1500 platform can have multiple time slots in the T1 data stream assigned to each physical slot in the channel bank. The Total Access 1500 allows craft selectable time slots using the electronic provisioning interface. The system will automatically map DS0s in the T1 as determined by the LIU operational configuration. Manual mapping is available via the LIU menu.

Connections

Four 50-pin male amphenol connectors on the rear of the Total Access 1500 chassis provide the interconnect wiring for each of the access module physical slots. The Dual 4-Wire TO requires P1 (T/R) and P2 (T1/ R1) for the odd ports of each access module, while P3 (T/R) and P4 (T1/R1) for the even ports. See Table 2 for wiring interconnect details.

2

Section 61180212L2-5, Issue 1

61180212L2-5A

Image 2
Contents General ContentsTables Compliance Codes InstallationCompliance Time Slot AssignmentsTime Slot and Wiring Interconnect Dual T1 Quad T1 D4 Quad T1 D1DD14 Provisioning Password and User IDDual 4-Wire to Options Menu NavigationWarranty and Customer Service MaintenanceSpecifications Specifications PerformanceL2-5, Issue