ADTRAN SHDSL NxNTU Bit Error Rate Test, Searching for pattern The Bert has lost pattern sync

Page 13
(Figure 13).

Bit Error Rate Test

The SHDSL NTU contains a built-in Bit Error Rate Test (BERT). The BERT involves injecting and detecting a Pseudorandom Binary Sequence (PRBS) toward the network on the selected payload (i.e. G.703, Nx64, or entire SHDSL payload). The PRBS used in the SHDSL NTU is PRS15 as defined in ITU-T O.150 and O.151. It is also known as a 2e-15 pattern.

The BERT is only accessible via the VT100 terminal screens. Select “4. Test” from the Main Menu Screen. From the Test Screen, the SHDSL BERT, G.703 BERT, and Nx64k BERT options will appear, and each has one of the following status messages: N/A – This BERT is currently unavailable. Only one BERT can be active at a time. For example, if SHDSL BERT is active, all others will be N/A.

ACTIVE – This BERT is currently in progress. The source column identifies the person who initiated the BERT.

INACTIVE – This BERT is not currently in progress. After selecting a BERT type from the Test Screen, the BERT Screen will appear, illustrating both BERT statistics and commands.

If no BERT is currently active, the following list of commands will be available:

Start – Starts the BERT on the selected port/service.

If the BERT is currently active, the following list of commands will be available:

Stop – Stops the BERT in progress.

Inject a Single Bit Error – Injects one bit error into the pattern.

Restart – Clears out all statistics and restarts the BERT.

In addition to the commands, the following statistical information is provided:

Bit Error Rate – Total number of bit errors divided by the total number of bits in the current test interval.

Bit Error Count – Total number of bit errors in the current test interval.

Pattern Sync Loss Count – Total number of times that the BERT has lost pattern sync.

Errored Seconds – Total number of seconds in which at least one bit error has occurred.

Total Elapsed Time – Total time that has elapsed since the test began (Days: Hours: Minutes: Seconds).

A BERT status field supplies the following information:

On – The BERT has started and has pattern sync.

Searching for pattern – The BERT has lost pattern sync.

Off – This BERT is currently off.

Loopbacks

There are five types of local loopbacks and five types of remote loopbacks available for each of the three line interfaces (V.35, G.703, and SHDSL). When initiating a loopback, the first step is choosing a line interface. When V.35 is chosen, the loopback will occur at the V.35 drivers and receivers. When G.703 is chosen, the loopback will occur at the G.703 drivers and receivers. When SHDSL is chosen, the loopback will occur at the SHDSL drivers and receivers.

NOTE

All remote loopbacks are initiated at the local Express 6530 unit.

Local Dual SidedNTULoopback – ProvidesLTUa bidirectional loopback at the NTU (Figure 12).

Figure 12. Local Dual Sided Loopback

Remote Dual SidedNTULoopback – InitiatedLTU at the NTU and provides bidirectional loopback at the LTU

Figure 13. Remote Dual Sided Loopback

61225101L1-5B

13

Image 13
Contents General L1-5B Issue 2, DecemberLED Descriptions Front Panel FeaturesStatus Description Button Label Description Front Panel PushbuttonsConnections Back Panel FeaturesShdsl Pin Connections 703 Pin Connections21 Pin Connections 28 Pin ConnectionsCircuit Number Circuit Name To/From DCE Pinout A/B 36 Pin Connections 35 Pin ConnectionsExpress 6530 Strap Map Optioning Hardware OptioningExpress 6530 Menu Tree Cross-Connect Map Full Nx64k Service Full G.703 ServiceService Time Slots Tab. Select Shdsl or G.703 TimeslotsTypical Applications Framed Full E1 ServiceBack-to-Back NTU Operation Full Nx64k 2 Mbps ServiceSearching for pattern The Bert has lost pattern sync Bit Error Rate TestLoopbacks Remote Customer Transparent Loopback Local Customer Transparent Loopback ProvidesLocal Network Transparent Loopback Provides a VT100 Test Screens Loopback OverviewOperation Multiple Services61225101L1-5B Express 6530 Shdsl NxNTU Specifications SpecificationsWarranty and Customer Service 61225101L1-5B