NOTE
Do not use in
2. OPTIONS
Select the appropriate OPTIONS and RATE using SW1 and faceplate switches as illustrated in Figure 3 and Figure 4.
NOTE
The TROCU DP must be used with an appropriate
Features
In addition to operation over extended ranges the TROCU DP incorporates or supports the following:
CAUTION
Select only one option rate. Rate is selected on faceplate switch SW2 by pushing one or two switches to the right toward the inscribed rates. If either SW56 or 64 is selected, the secondary channel (SC) switch may not be selected.
•
•Repeaterless operation.
•Bridged tap tolerant
•Span power for remote
•Utilization in all D4 channel bank and
•NEAR and FAR logic level bantam test access.
A/B Signaling
When A/B Signaling
•Loop Quality Monitor and A/B signaling options.
•Embedded Digital System 6 capabilities for remote provisioning, configuration, and performance monitoring.
NOTE
A/B option is only applicable when SW56 is selected; otherwise the option is a “don’t care.”
Quality Monitor
Line Code |
| When Quality Monitor | |||||
The ADTRAN TRDDS incorporates Simple Coded- | monitors the incoming | ||||||
Pulse Amplitude Modulation (SC PAM), a line code | customer interface data for errors. If excessive errors | ||||||
that reduces the bandwidth needed to transport signals | are detected, the unit blocks customer data |
| |||||
over copper loops. The Power Spectrum Density | transmission and sends Abnormal Station Code to the | ||||||
(PSD) of SC PAM complies with Basic Rate Interface | network. Customer data transmission is automatically | ||||||
(BRI) PSD mask as specified in ANSI T1.601 and is | restored when the trouble condition is cleared. The | ||||||
below allowable 2B1Q PSD levels. SC PAM | Quality Monitor feature is recommended for use on | ||||||
increases the deployment ranges and allowable | multipoint circuits. |
|
| ||||
bridged tap lengths when compared to AMI and |
|
|
|
|
| ||
2B1Q. Additionally, SC PAM has an improved |
|
|
|
|
| ||
spectral compatibility when compared to AMI and |
|
|
|
|
| ||
2B1Q. |
|
|
|
| 8 | SC | |
|
|
|
|
| |||
|
|
|
|
| 7 | 64 | |
|
|
|
|
|
| ||
Sealing Current |
|
|
|
| 6 | 56 | |
|
|
|
|
| |||
The TROCU DP provides a constant 10 mA sealing | SW1 | ON |
| 5 | 19.2 | ||
|
| ||||||
OFF | 1 | A/B Signaling | 3 4 | 9.6 | |||
current to the | |||||||
4.8 | |||||||
OFF | Quality Monitor | ||||||
and span power of | 2 |
| 2.4 | ||||
| 2 | ||||||
|
|
| |||||
|
|
|
| ||||
system is in the A3 Class as specified in Bellcore |
|
|
| 1 | SW56 | ||
|
|
|
| ||||
|
|
| ON |
| |||
Network Telecommunications Equipment. |
| Figure 3. | Option | Figure 4. Rate | |||
|
| ||||||
|
|
| Switch | ||||
|
|
| Selection | ||||
|
|
|
|
| |||
2 | Section 61291006L2, Issue 2 |
|
|