In lieu of option switches, the TROCU DP Preferred Option has been preprovisioned with feature settings as indicated in Table 1.
Table 1. Preprovisioning
Feature | Setting | |
|
| |
Latching Loopback | ON | |
|
| |
Zero Code Suppression | ON (Unless 56 kbps, SC, and | |
64 kbps = OFF) | ||
| ||
|
| |
Error Correction | OFF | |
|
|
3. INSTALLATION
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
The TROCU DP plugs directly into a WECO or equivalent D4 channel bank or the ADTRAN ACT 1900/2300 channel bank. No special wiring is required. The
When inserted into a powered up backplane the TROCU DP and
4. TESTING
Testing for the TROCU DP is accomplished using the same test procedures for
The TROCU DP is equipped with logic level bantam test access jacks that permit testing in both directions using a portable test set. Latching and alternating OCU and CSU loopback sequences are supported. Alternating loopbacks do not operate when the 64 kbps data rate is selected. Choose NEAR to test toward the customer loop; choose FAR to test toward the
In the FAR direction, an OCU loopback sequence will loop the unit directly across the
NOTE
If 64 kbps is selected, the unit will only respond to latching loopback sequences. Alternating sequences are not valid at this rate.
Table 2. Cable Type Loss Data @ 13.3 kHz
|
| Plastic Cable | dB Loss/kft |
| Paper Cable | dB Loss/kft |
|
|
|
|
|
|
|
|
|
| 19 | Gauge PIC (0F) | 0.5302 | 19 | Gauge PULP (0F) | 0.5616 |
|
| 19 | Gauge PIC (70F) | 0.6083 | 19 | Gauge PULP (70F) | 0.6415 |
|
| 19 | Gauge PIC (120F) | 0.6610 | 19 | Gauge PULP (120F) | 0.6955 |
|
|
|
|
|
|
|
|
|
| 22 | Gauge PIC (0F) | 0.912 | 22 | Gauge PULP (0F) | 0.9454 |
|
| 22 | Gauge PIC (70F) | 1.0258 | 22 | Gauge PULP (70F) | 1.0606 |
|
| 22 | Gauge PIC (120F) | 1.1015 | 22 | Gauge PULP (120F) | 1.1370 |
|
|
|
|
|
|
|
|
|
| 24 | Gauge PIC (0F) | 1.2571 | 24 | Gauge PULP (0F) | 1.2900 |
|
| 24 | Gauge PIC (70F) | 1.3982 | 24 | Gauge PULP (70F) | 1.4324 |
|
| 24 | Gauge PIC (120F) | 1.4917 | 24 | Gauge PULP (120F) | 1.5268 |
|
|
|
|
|
|
|
|
|
| 26 | Gauge PIC (0F) | 1.6823 | 26 | Gauge PULP (0F) | 1.6751 |
|
| 26 | Gauge PIC (70F) | 1.8568 | 26 | Gauge PULP (70F) | 1.8469 |
|
| 26 | Gauge PIC (120F) | 1.9718 | 26 | Gauge PULP (120F) | 1.9608 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Section 61291006L2, Issue 2 | 3 |