6.REMOTE PROVISIONING AND DIAGNOSTICS
Control Protocol
Remote access to provisioning and status information is accomplished using ADTRAN Digital System 6 Message protocol, defined in Control and Diagnostic Procedures Practice, Section
NOTE
The REACT 2001 GUI software Release 1.900 supports ANSI
Remote access is accomplished using a defined set of inband DS0 byte sequences similar to the latching loopback sequence. Commands issued through the test system are recognized by the individual channel unit, which responds with the appropriate byte sequences. These inband commands may be used to verify options via dialogs with REACT 2001 and TPI 108/109 test sets. Unit CLEI, serial number, provisioning, and performance information can be retrieved remotely using the Digital System 6 protocol.
Provisioning and Status
All configuration options can be remotely viewed or provisioned. The front panel AP LED indicator Flashes during control link establishment and remains ON after the IDSL
If the IDSL
The AP LED remains ON when the IDSL
7. MAINTENANCE
The T200 IDSL
8. DEPLOYMENT GUIDELINES
The IDSL
•All loops must be nonloaded.
•Actual Measured Loss (AML) should not exceed 40 dB at 40 kHz (135 Ω termination), the Nyquist frequency of a
•Total bridged tap length should not exceed 2 kft.
NOTE
If any of the above Deployment Guideline criteria are not met, design should be considered using Total Reach DDS, with the exception of the first bullet.
9.WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within 10 years from the date of shipment if it does not meet its published specifications or fails while in service (see ADTRAN Carrier Networks Equipment Warranty, Repair, and Return Policy and Procedure, document
Contact Customer and Product Service (CAPS) prior to returning equipment to ADTRAN.