Cross-Connect Map
The purpose of the
The
0. Idle
If a time slot is set for idle, an idle code is inserted. The pattern will always be FF hex (all 1s) toward the SHDSL network.
The idle pattern out the G.703 interface is programmable under the G.703 option. The default is value FF hex (all 1’s).
1. - 31. G.703 Service
The selected time slot will carry G.703 service (Refer to the Full G.703 Services subsection for more information).
32. G.704 Framing
This option enables three different framing configurations. Framing is always set in the first time slot (TS0). The framing will be locally generated if 32 is entered in the G.703 TS0 slot only. If 32 is entered in the G.703 TS0 and the SHDSL TS0, then the framing will be passed transparently between the G.703 and SHDSL ports. If values other than 32 are assigned to both the SHDSL TS0 slot and G.703 TS0 slot then the operation is G.703 unframed (if other G.703 service values are assigned to the G.703 time slots).
33. Nx64K Service
The selected time slot will carry Nx64K service. The value assignment is only valid for the SHDSL time slots.
A. Apply New Map
This command saves and activates any changes made by the user.
U. Undo New Map
This command will undo any changes made by the user since the last saved configuration. The new pending map will revert to the currently active time slot assignments.
Circuit | ID: |
|
|
|
|
|
|
|
| 22:03:22 | ||
Unit Mode: | NT |
| Provisioning Type: Local |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| |||
|
| SHDSL Timeslots |
|
|
| G.703 Timeslots |
|
| ||||
TS0 | = | 32 | TS12 = 1 | TS24 | = 1 | TS0 | = | 32 | TS12 = 1 | TS24 | = 1 | |
TS1 | = | 1 | TS13 = 1 | TS25 | = 1 | TS1 | = | 1 | TS13 = 1 | TS25 | = 1 | |
TS2 | = | 1 | TS14 = 1 | TS26 | = 1 | TS2 | = | 1 | TS14 = 1 | TS26 | = 1 | |
TS3 | = | 1 | TS15 = 1 | TS27 | = 1 | TS3 | = | 1 | TS15 = 1 | TS27 | = 1 | |
TS4 | = | 1 | TS16 = 1 | TS28 | = 1 | TS4 | = | 1 | TS16 = 1 | TS28 | = 1 | |
TS5 | = | 1 | TS17 = 1 | TS29 | = 1 | TS5 | = | 1 | TS17 = 1 | TS29 | = 1 | |
TS6 | = | 1 | TS18 = 1 | TS30 | = 1 | TS6 | = | 1 | TS18 = 1 | TS30 | = 1 | |
TS7 | = | 1 | TS19 = 1 | TS31 | = 1 | TS7 | = | 1 | TS19 = 1 | TS31 | = 1 | |
TS8 | = | 1 | TS20 = 1 | TS32 | = N/A | TS8 | = | 1 | TS20 = 1 |
|
| |
TS9 | = | 1 | TS21 = 1 | TS33 | = N/A | TS9 | = | 1 | TS21 = 1 |
|
| |
TS10 = | 1 | TS22 = 1 | TS34 | = N/A | TS10 | = | 1 | TS22 = 1 |
|
| ||
TS11 = | 1 | TS23 = 1 | TS35 | = N/A | TS11 | = | 1 | TS23 = 1 |
|
| ||
| Timeslot | Assignments |
|
|
|
| Commands |
|
| |||
| 0. | Idle |
|
| A. | Apply New Map | G. | Full G.703 Service | ||||
G.703 Service | U. | Undo New | Map | N. | Full Nx64K Service | |||||||
| 32. | G.704 Frame |
| Tab. Select | SHDSL or G.703 Timeslots | |||||||
| 33. | Nx64K Service |
|
| Arrow Keys. | Move Cursor |
|
| ||||
|
|
|
| G.704 | Framing = LT Delivered |
|
|
|
|
Figure 6. Cross-Connect Map
9 |