116B
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at:
http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php
Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/
Model Number | Indoor Coil Model Number | Furnace Model Number | Cooling Capacity | EER | SEER |
116BNA018****B | CNPV*1917A** |
| 18,000 | 12.0 | 14.5 |
116BNA024****A | CNPV*3117A** |
| 23,600 | 12.0 | 14.5 |
116BNA030****A | CNPV*3117A** |
| 28,600 | 12.0 | 14.5 |
116BNA036****A | CNPV*3717A** |
| 34,400 | 12.0 | 14.5 |
116BNA042****A | CNPV*4324A** |
| 41,500 | 12.0 | 14.5 |
116BNA048****B | CAP**6025A** |
| 46,000 | 12.0 | 14.5 |
116BNA049****A | CAP**6025A** |
| 48,000 | 11.5 | 14.0 |
116BNA060****A | CNPV*6124A** |
| 56,000 | 12.0 | 14.5 |
116BNA061****A | CNPV*6124A** |
| 59,500 | 12.0 | 14.5 |
*AHRI = Air Conditioning, Heating & Refrigeration Institute EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
12