MODEL NUMBER NOMENCLATURE

12345678910111214
N N N A A/N N N N N A/N A/N N A
116BNA03600 00
Prod-
uct
Family
Tier SEER Major
Series Voltage Grille
Variations
Cooling Capacity Open Open Open Series
1=AC
1=
Legacy
RNC
6=16 SEER B=Puron
N=
208--- 230---1
or
208/230--- 1
A=Dense 0=Not
Defined
0=Not
Defined
0=Not
Defined
the environmentally sound refrigerant
REGISTERED
ISO 9001:2000
This product has been designed and manufactured to
meet Energy Star®criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.

STANDARD FEATURES

Feature 018 024 030 036 042 048 / 049 060 / 061
Puron Refrigerant XXXXXXX
Maximum SEER * 16.0 16.0 16.5 16.5 16.0 16.0 16.0
Scroll Compressor XXXXXXX
FieldInstalledFilterDrier XXXXXXX
Front Seating Service Valves XXXXXXX
Internal Pressure Relief Valve XXXXXXX
Internal Thermal Overload XXXXXXX
Long Line capability XXXXXXX
Low Ambient capability with Kit XXXXXXX
Dense Grille XXXXXXX
* With approved combinations
X=Standard

PHYSICAL DATA

UNIT SIZE --- VOLTAGE, SERIES 018 --- B 024 --- A 030 --- A 036 --- A 042 --- A 048 --- B 049 --- A 060 --- A 061 --- A
Operating Weight lb (kg) 125
(56.7)
147
(66.5)
153
(69.3)
165
(74.8)
213
(96.4)
264
(119.7)
231
(104.8)
272
(123.4)
272
(123.4)
Shipping Weight lb (kg) 154
(69.9)
183
(82.8)
188
(85.2)
204
(92.5)
254
(115.2)
317
(143.8)
269
(222.0)
310
(140.6)
310
(140.6)
Compressor Type Scroll
REFRIGERANT Puron®(R---410A)
Control TXV (Puron®Hard Shutoff)
Charge lb (kg) 4.60
(2.09)
6.00
(2.72)
6.81
(3.09)
7.00
(3.18)
8.62
(3.91)
13.0
(5.90)
9.00
(4.08)
14.50
(6.58)
14.50
(6.58)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical Vertical
Air Qty (CFM) 1881 2614 2614 3223 3810 4046 4046 4046 4046
Motor HP 1/12 1/10 1/10 1/12 1/5 1/4 1/4 1/4 1/4
Motor RPM 1100 1100 1100 800 800 800 800 800 800
COND COIL
Face Area (Sq ft) 11.50 15.10 17.20 17.60 25.15 25.15 25.15 30.15 30.15
Fins per In. 25 25 25 25 25 20 20 20 20
Rows 1 1 1 1 1 2 1 2 2
Circuits 3 4 4 4 6 7 7 8 8
VALVECONNECT.(In.ID)
Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8
Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor* 3/4 7/8 1 --- 1 / 8
Max Liquid Line {3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
{See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.
116B