ADTRAN D4 TRI-C DP warranty Logic Bantam Jacks, Hardware Switches SW1 & SW2, Faceplate Switches

Page 1

JOBAID

TRI - C DP / D4

PRICING AND AVAILABILITY

800.827.0807

TECHNICAL SUPPORT 800.726.8663

RETURN FOR REPAIR

256.963.8722

www.adtran.com

61102182L1-22A 0105

TRI-C DP / D4

CLEI: D4D3MU0D_ _

TRI-C DP

1102182L1

STATUS LEDs

LP

OFF

TRI loop sync has been established and no Near End Block Errors

 

 

(NEBE) are being received from the loop interface

 

RED

TRI-interface is out of sync or there is loss of signal

 

YELLOW

Indicates a BER of 10-5has been detected

 

FLASHING

Flashes upon receipt of a Near End Block Error (NEBE) or when a

 

 

BER > 10-6is detected during Local Performance Monitoring

LOGIC BANTAM JACKS

Used to perform upstream and downstream testing with a DS0 level tester such as a TPI 108/109 or Fireberd 4000/6000.

Rx (OUT) – transmits signal out to unit being tested Tx (IN) – receives signal in from unit being tested

HARDWARE SWITCHES SW1 & SW2

LP

CR

ACT TEST

ERR

LPBK CRTX

AD6LPTX

AD5NT1

AD4AD1

AD3 AD2

 

TEST

B1

B2

NORM

PTRN

CR

OFF

Carrier sync (framing per TR-TSY-000397) has been established

 

 

and no Near End Block Errors are being received frrom the carrier

 

 

interface

 

RED

No framing pattern is being received

 

YELLOW

A BER > 10-5 has been detected

 

FLASHING

Flashes upon receipt of a Near End Block Error (NEBE) or when a

 

 

BER > 10-6 is detected during Local Performance Monitoring

ACT

GREEN

Layer 1 from the ISDN switch to the customer ISDN terminal

 

 

equipment has been established

TEST

GREEN

Unit is in Local Performance Monitoring mode or the local test

 

 

pattern gen/det in invoked

SW1-1: TRM – along with SW1-2, selects the bank type for the U-BR1TE IV

SW1-2: TRM

Bank

Count/Slot

SW1-1

SW1-2

D4

D4 Counting

On

Off

 

D1D Counting

On

On

SLC I

CU in slots 1,4,7,10

On

On

 

CU in slots 2,5,8,11

Off

Off

SLC III

D4 Counting

On

On

 

D1D Counting

Off

On

 

 

 

 

SW1-3: B1 –along with SW4 and SW5, selects the service level

OUT

 

L

(Rx)

 

O

 

 

G

IN

 

I

 

C

(Tx)

 

 

 

 

 

 

 

 

YELLOW

Front panel test has been successssfully initiated or unit is

 

 

responding to a 2B+D loopback request

 

FLASHING

Flashes once every two seconds when responding to a B1 loopback

 

 

request or when forced into a B1 loopback from the front panel.

 

 

Flashes twice every two seconds when responding to a B2 loopback

 

 

request or when forced into a B2 loopback from the front panel.

ERR

FLASHING

Errors detected by local test pattern detector

FACEPLATE SWITCHES

Rotary Switch - used to select circuit elements for loopback testing

AD1 – selects address of local unit for loopback

AD2 – selects address of next unit downstream for loopback

AD3 – selects address of second unit downstream for loopback

AD4 – selects address of third unit downstream for loopback

AD5 – selects address of fourth unit downstream for loopback

AD6 – selects address of fifth unit downstream for loopback

LPBK – forces this unit to set up bidirectional loopback for selected B1 or B2 channel

CRTX – sets up loopback toward carrier

LPTX – sets up loopback toward the loop

NT1 – selects address of the NT1 for loopback

TEST – initiates selected loopback test from rotary switch

SW1-4: B2

SW1-5: D

Service Option

SW1-3

SW1-4

SW1-5

 

(B1)

(B2)

(D)

2B+D

On

On

On

2B

On

On

Off

B1+D

On

Off

On

B2+D

Off

On

On

B1

On

Off

Off

B2

Off

On

Off

D

Off

Off

On

 

 

 

 

SW1-6: Zero Byte Substitution (ZBS)

Enables or disables ZBS

Note: ZBS must be set the same for the COT and RT. For AMI-provisioned carriers,

ZBS should be enabled. Setting is optional for B8ZS-provisioned carriers.

COMPLIANCE

This product is intended to be installed

Code

Input

Output

Power Code (PC)

F

C

in products providing a Type “B” or “E”

enclosure and in restricted access location

Telecommunication Code (TC)

X

only.

Installation Code (IC)

A

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

DIP SWITCHES

B1/B2 – selects which B channel, B1 or B2, to be tested during local tests

NORM/PTRN – used to select whether test pattern is sent from a test set or the unit itself NORM – test pattern is sent from test set plugged into faceplate bantam jacks

PTRN – test pattern, 2047, is internally generated and transmitted

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty, call

(877) 457-5007, Document #414.

HANDLING PRECAUTIONS REQUIRED.

■ For a complete Installation and Maintenance Practice: (877) 457-5007, Document # 427. Please have your fax number available. ■

Image 1
Contents Faceplate Switches Hardware Switches SW1 & SW2DIP Switches Warranty