ADTRAN T200 H4TU-R specifications Table A-2. Loopback Control Codes

Page 24

Table A-2. Loopback Control Codes (Continued)

Function

Code (Hex / Binary)

Response

 

 

 

Span Power Disable1

6767 or

If the units are armed and 6767 is sent from the network, the

 

0110 0111 0110 0111

H4TU-C will disable span power. If the pattern is sent from

 

 

the network, the span power will be disabled as long as 6767

 

 

pattern is detected. Once the pattern is no longer received, the

 

 

H4TU-C will reactivate span power. All units will then retrain

 

 

and return to the disarmed and unlooped state.

 

 

 

First H4R Loop Up 1,2

C741

If one or more H4Rs are present, the H4R closest to the

 

1100 0111 0100 0001

H4TU-C will loop up toward the network, 2 seconds of AIS

 

 

(all ones) will be transmitted, the looped data will be sent for 5

 

 

seconds, and then a burst of 10 logic errors will be injected.

 

 

The burst of 10 logic errors will continue every 20 seconds as

 

 

long as the C741 pattern is detected. When the pattern is

 

 

removed, the unit will remain in loopback. If the pattern is

 

 

reinstated, the injection of 10 logic errors will continue every

 

 

20 seconds.

 

 

 

Second H4R Loop Up 1,2

C754

If two H4Rs are present, the second H4R from the H4TU-C

 

1100 0111 0101 0100

will loop up toward the network, 2 seconds of AIS (all ones)

 

 

will be transmitted, the looped data will be sent for 5 seconds,

 

 

and then a burst of 200 logic errors will be injected. The burst

 

 

of 200 logic errors will continue every 20 seconds as long as

 

 

the C754 pattern is detected. When the pattern is removed, the

 

 

unit will remain in loopback. If the pattern is reinstated, the

 

 

injection of 200 logic errors will continue every 20 seconds.

 

 

 

H4TU-R Address 20 for

C742

If armed, the H4TU-R will loop up toward the network, 2

Extended Demarc 1,2

1100 0111 0100 0010

seconds of AIS (all ones) will be transmitted, the looped data

 

 

will be sent for 5 seconds, and then a burst of 20 logic errors

 

 

will be injected. The burst of 20 logic errors will continue

 

 

every 10 seconds as long as the C742 pattern is detected.

 

 

When the pattern is removed, the unit will remain in loopback.

 

 

If the pattern is reinstated, the injection of 20 logic errors will

 

 

continue every 10 seconds.

 

 

 

1.Units must be armed with 11000b or FF48h before this code will work.

2.Loopback and error injection will only occur if the in-band code is received by the unit that is to go into loopback. In other words, if another loopback blocks the in-band code from being transmitted to the unit that is to go into loop- back, loopback and error injection will not occur.

Note: All codes listed above must be sent for a minimum of 5 seconds to be detected and acted upon

A-4

Issue 1, December 2003

61223424L2-5A

Image 24
Contents L2-5A Issue 1, December Clei Code T1L497PC GeneralRevision History Installation DescriptionH4TU-R Enclosure Compatibility ComplianceFront Panel LED Indicators Front Panel LED Indicators Name Indication DescriptionOFF Provisioning Option Option Settings Default Settings Remote ProvisioningProvisioning Options HDSL4 System Testing ConnectionsDS1 MON Bantam Jacks H4TU-R Network Loopbacks Customer LoopbacksFront Panel Operation Control Port OperationOperation Adtran Adtn H4TU-C H4TU-RT1L7PODAAA AdtnB8ZS ESFAIS/CI AutoLoop Margin AttenCUR/MIN/MAX CUR/MAX H4R1 NetwES-L CV-LH4TUC DSX-1 H4TUR LoopSES-L UAS-LLOSS-L PDVS-LLocation Alarm Current CountLast YellowraiLast Current Count Span C-H1 LOS H4TU-C MrgnH4R1 NET Mrgn H4TU-C AttenSystem PM/Screen Report Option Troubleshooting Screen CSTGeneral Information Screen HDSL4 Deployment Guidelines Attenuation limitsRange Limits 26 Gauge / 70F / PIC Range Limits 24 Gauge / 70F / PICMaintenance SpecificationsWarranty and Customer Service Troubleshooting GuideHDSL4 T200 H4TU-R Specifications Specification DescriptionTC PAM HDSL4 Maintenance Modes Loopback Process DescriptionLoopback Control Codes Table A-1. HDSL4 Loopback Control Codes Type Source1 Code2,3 NameTable A-2. Loopback Control Codes Function Code Hex / Binary ResponseH4TU-C H4TU-RTable A-2. Loopback Control Codes This page is intentionally blank Issue 1, December

T200 H4TU-R specifications

The ADTRAN T200 H4TU-R is a versatile and advanced telecommunications device designed for high-speed data transmission and enhanced connectivity. It serves primarily in carrier-grade applications, enabling service providers to deliver reliable broadband services to their customers. This device integrates multiple features and technologies that ensure optimal performance and flexibility in various networking environments.

One of the key features of the T200 H4TU-R is its ability to support high-speed data services over existing copper or fiber infrastructures. It utilizes G.SHDSL technology, which allows for symmetrical data rates ranging from 192 kbps to 5.7 Mbps, making it suitable for both enterprise and residential applications. This capability is essential for businesses requiring dedicated bandwidth for applications like VoIP, video conferencing, and cloud services.

The T200 H4TU-R also supports various interface options, including Ethernet over G.SHDSL and T1/E1 lines, which provides compatibility with multiple legacy systems. This flexibility extends the useful life of existing networks while enabling a smoother transition to newer technologies. The device features dual Gigabit Ethernet ports, allowing for easy integration into modern networking setups while facilitating network redundancy and load balancing.

Built with scalability in mind, the T200 H4TU-R can accommodate the growing demands of service providers. Its management capabilities are further enhanced by support for SNMP and Web-based interfaces, enabling operators to monitor network performance and promptly address any issues that arise.

Another significant characteristic of the T200 H4TU-R is its robust error correction capabilities, which ensure data integrity and minimize the risk of data loss during transmission. It employs advanced technologies such as H4 (High Capacity) coding and interleaved mode, effectively increasing data rates while maintaining reliability.

For installations, the device offers versatile powering options, including Power over Ethernet (PoE), which simplifies deployment while reducing cabling requirements. Additionally, its compact form factor enhances space efficiency in network closets.

In summary, the ADTRAN T200 H4TU-R delivers a powerful combination of speed, reliability, and flexibility. Its advanced G.SHDSL technology, support for various interface types, robust error correction, and management capabilities make it an ideal choice for service providers looking to enhance their broadband offerings while ensuring future scalability and performance.