3.3 Isolated Digital I/O Connections

3.3.1 Dry/Wet Contact Support for Digital Input

Each digital input channel accepts either dry contact or 0 ~ 5 VDC wet contact inputs. Dry contact capability allows the channel to respond to changes in external circuitry (e.g., the closing of a switch in the external circuitry) when no voltage is present in the external circuit. Figure 3-1 shows external circuitry with both wet and dry contact components, con- nected as an input source to one of the card's digital input channels.

Figure 3.2: Isolated Digital Input Connections

USB-4750 User Manual

14

Image 20
Contents USB-4750 Channel Isolated Digital I/O USB ModuleCopyright Acknowledgements Product Warranty 2 years Document Feedback Safety Precaution Static ElectricityTechnical Support and Assistance Contents Page Introduction Hardware Features \Program Files\Advantech\ADSAPI\Examples Software OverviewMore on the CD Page Installation Unpacking After taking out the module, you should firstDriver Installation Page Hardware Installation Hardware UninstallationUnplug or Eject Hardware Dialog Signal Connections Pin Assignments I/O ConnectorsOverview 2 I/O Connector Signal Description LED Indicator Status DescriptionIsolated Digital I/O Connections 1 Dry/Wet Contact Support for Digital InputIsolated Digital Output Connections Isolated Digital Output ConnectionsField Wiring Considerations Specifications Isolated Digital Input Isolated Digital OutputIsolated Counter General