Advantech USB-4750 user manual Isolated Digital Output Connections

Page 21

3.3.2 Isolated Digital Output Connections

Each of 8 isolated digital output channels comes equipped with a Darling- ton transistor. Every 8 output channels share common collectors and inte- gral suppression diodes for inductive loads. Channels 0 ~ 7 use COM0, and channels 8 ~ 15 use COM1 as a common pin. If an external voltage (5

~40 V) is applied to an isolated output channel (IDO 0 ~ IDO 15) while it is being used as an output channel, the current will flow from the external voltage source to the card. Please take care that the current through each GND pin not exceed 100 mA.

Figure 3.3 shows how to connect an external output load to the card's iso- lated outputs.

Figure 3.3: Isolated Digital Output Connections

15

Chapter3

Image 21
Contents Channel Isolated Digital I/O USB Module USB-4750Copyright Acknowledgements Product Warranty 2 years Safety Precaution Static Electricity Technical Support and AssistanceDocument Feedback Contents Page Introduction Hardware Features Software Overview More on the CD\Program Files\Advantech\ADSAPI\Examples Page Installation After taking out the module, you should first UnpackingDriver Installation Page Hardware Uninstallation Hardware InstallationUnplug or Eject Hardware Dialog Signal Connections I/O Connectors OverviewPin Assignments LED Indicator Status Description 2 I/O Connector Signal Description1 Dry/Wet Contact Support for Digital Input Isolated Digital I/O ConnectionsIsolated Digital Output Connections Isolated Digital Output ConnectionsField Wiring Considerations Specifications Isolated Digital Output Isolated Digital InputIsolated Counter General