Campbell Hausfeld CW301400AJ Instrucciones para operar Continuación, Operating Procedure

Page 2

Additional Operating Instructions

CW301300AJ, CW301400AJ

Instrucciones Adicionales

CW301300AJ, CW301400AJ

New Switch Installation (Continued)

in kit. Insert motor and line cord into switch. Tighten strain relief clamp screw to hold cords securely.

8.Position black motor wire underneath screw head #4 (See Fig. 4), then tighten screw to secure wire. Position black line wire underneath screw head #3, then tighten screw to secure wire.

9.Position white line wire underneath screw head #1, then tighten screw to secure wire. Position white motor wire underneath screw head #2, then tighten screw to secure wire (See Fig. 4).

10.Attach green ground wire from line cord to inside of pressure switch with ground screw provided in kit. Repeat procedure with green ground wire from motor cord. (See Fig.4

IMPORTANT: Read

instructions before operating

compressor or damage may MANUAL result.

1.Turn switch to OFF position and plug in power cord (Fig. 6).

2.Turn switch to AUTO position to run unit (Fig. 6).

Instrucciones para operar (Continuación)

IMPORTANTE: Lea estas

 

 

 

instrucciones antes de operar

 

 

 

 

 

el compresor o podría dañarlo.

 

MANUAL

 

 

 

 

 

 

 

 

 

 

 

 

1.

Coloque el presostato en “off” y

 

conecte el cordón eléctrico al

 

tomacorrientes (Fig. 6).

2.

Coloque el presostato en “auto”

 

para operar la unidad (Fig. 6).

4.Conecte el extremo de la manguera a la perilla del regulador. Gire el regulador en sentido horario para aumentar la presión que sirve la herramienta que está usando.

AVISO Este

pre-

sostato debe estar en OFF cuando vaya a conectar o desconectar el cordón eléctrico del tomacorrientes

A

FF

U

 

TO / O

Figura 6

1

2

LINE

MOTOR

LINE

MTR

3

4

Ground terminals

Figure 4

11.Place cover on pressure switch and tighten cover screw.

12.Screw regulator onto pressure switch.

NOTE: Ensure air flow indicator arrow on regulator body points away from compressor (See Fig. 5).

Hose

Outlet

Air Flow

Figure 5

13.Attach outlet pressure gauge to regulator.

Operating Procedure

In the AUTO position, the compressor pumps air into tank. It shuts off automatically when unit reaches its maximum preset pressure. In the OFF position, the pressure switch cannot function and the compressor will not operate.

A

FF

U

 

TO / O

Figure 6

3.Turn regulator knob fully counterclockwise. Compressor will build to maximum preset pressure and shut off.

4.Attach end of hose to regulator knob. Turn regulator clockwise to increase pressure going to the tool that is being used.

 

 

This switch should

 

NOTICE

 

be in the OFF

 

 

position when connecting or

disconnecting the power cord from the electrical outlet.

3. Gire la perilla del regulador

completamente en sentido contrario

a las agujas del reloj. El compresor

alcanzará la presión máxima fijada

de fábrica y se apagará.

Notas

Replacement Parts List - See Figure 2

Ref.

No.Description

1Bushing Reducer

2Strain Relief Clamp (ST/SJT) Strain Relief Clamp (SJT/SJT)

3ASME Safety Valve (140 psi) (CW301300AJ) ASME Safety Valve (115 psi) (CW301400AJ)

41/4" Nipple

5Pressure Gauge

6Unloader Valve

7Pressure Switch (CW301300AJ) Pressure Switch (CW301400AJ)

8Regulator

9Quick Connect

10Unloader Tube

11Clamp Screw

12Ground Screw

www.chpower.com

Part Number

Qty

ST071407AV1

CW209500AV1

CW209600AV1

V-215100AV1

V-215102AV1

HF002401AV2

GA016302AV2

CW210000AV1

CW211200AJ1

CW213100AJ1

RE206203AV1

ST081301AV1

ST117803AV1

ST209800AV1

ST074407AV2

2

7

Image 2
Contents Description Removal of Existing SwitchNew Switch Installation ComponentsInstrucciones para operar Continuación Operating ProcedureReplacement Parts List See Figure No.DescriptionPièces Détachées Installation du Nouveau ManostatInstrucciones para operar Lista de repuestos Vea la FiguraDescripción Installation du Nouveau Manostat SuiteMéthode d’Opération Componentes