Dell R720XD System Setup Main Screen, System BIOS Screen, System Information Screen

Page 22
System Setup Main Screen

System Setup Main Screen

NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.

Menu Item

Description

System BIOS

This option is used to view and configure BIOS settings.

iDRAC Settings

This option is used to view and configure iDRAC settings.

Device Settings

This option is used to view and configure device settings.

System BIOS Screen

NOTE: The options for System Setup change based on the system configuration.

NOTE: System Setup defaults are listed under their respective options in the following sections, where applicable.

Menu Item

Description

System Information

Displays information about the system such as the system model name, BIOS version, Service

 

Tag, and so on.

Memory Settings

Displays information and options related to installed memory.

Processor Settings

Displays information and options related to the processor such as speed, cache size, and so

 

on.

SATA Settings

Displays options to enable or disable the integrated SATA controller and ports.

 

NOTE: This setting is not available on the PowerEdge R720xd.

Boot Settings

Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS

 

boot settings.

Integrated Devices

Displays options to enable or disable integrated device controllers and ports, and to specify

 

related features and options.

Serial Communication

Displays options to enable or disable the serial ports and specify related features and options.

System Profile

Displays options to change the processor power management settings, memory frequency,

Settings

and so on.

System Security

Displays options to configure the system security settings like, system password, setup

 

password, TPM security, and so on. It also enables or disables support for local BIOS update,

 

the power and NMI buttons on the system.

Miscellaneous

Displays options to change the system date, time, and so on.

Settings

 

System Information Screen

Menu Item

Description

System Model Name

Displays the system model name.

22

Image 22
Contents Regulatory Model E14S Series Dell PowerEdge R720 and R720xd Owners ManualRegulatory Type: E14S001 Notes, Cautions, and Warnings 2 Using The System Setup and Boot Manager Contents1 About Your System General Memory Module Installation Guidelines 3 Installing System ComponentsInstalling Memory Modules Internal USB Memory Key Optional Installing The Optional Hard-DriveBackplane Back 4 Troubleshooting Your SystemRemoving The Optional Hard-DriveBackplane Back 7 Technical Specifications 5 Using System Diagnostics6 Jumpers And Connectors Disabling A Forgotten PasswordFront-PanelFeatures And Indicators About Your SystemItem Item LCD Panel Features View Menu Setup MenuHome Screen Set errorDiagnostic Indicators Electrical indicator Condition See Getting HelpHard-DriveIndicator Patterns Connector Back-PanelFeatures And IndicatorsIndicator, Button, or PowerEdge R720Connector NIC Indicator CodesIndicator, Button, or ItemPower Indicator Codes Other Information You May Need Using The System Setup and Boot Manager Choosing The System Boot ModeResponding To Error Messages Entering System SetupSystem Setup Options Using The System Setup Navigation KeysSystem BIOS Screen System Setup Main ScreenSystem Information Screen Memory settings screen Processor Settings ScreenMenu Item SATA Settings Screen Boot Settings Screen Integrated devices screenSerial Communications Screen System Profile Settings Screen System Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning A System And/Or Setup Password To assign a system and/or setup password Using Your System Password To Secure Your System Entering The UEFI Boot ManagerOperating With A Setup Password Enabled Boot Manager Screen Using The Boot Manager Navigation KeysUEFI Boot Menu Changing The Thermal Settings iDRAC Settings UtilityEntering The iDRAC Settings Utility Embedded System ManagementFront Bezel Optional Installing System ComponentsRecommended Tools Removing The Front BezelOpening And Closing The System Installing The Front BezelOpening The System Inside The System Closing The Systemcooling-fanassembly Cooling Shroud Removing The Cooling ShroudInstalling The Cooling Shroud System memory•number of DIMMs populated per channel Processor General Memory Module Installation GuidelinesProcessor DIMM TypeMemory Optimized Independent Channel Mode Mode-SpecificGuidelinesAdvanced ECC Lockstep Memory SparingSample memory configurations Memory MirroringNumber of Removing Memory Modules 2.Open the system 3.Remove the cooling shroud Installing Memory Modules Hard Drives Removing A 2.5 Inch Hard-DriveBlank Installing A 2.5 Inch Hard-DriveBlankRemoving A 2.5 Inch Hard-DriveBlank Back Installing A 2.5 Inch Hard-DriveBlank Back Removing A 3.5 Inch Hard-DriveBlankInstalling A Hot-SwapHard Drive Installing A 3.5 Inch Hard-DriveBlankRemoving A Hot-SwapHard Drive Removing A Hard Drive From A Hard-DriveCarrier Optical Drive Optional Installing A Hard Drive Into A Hard-DriveCarrierRemoving The Optical Drive Installing The Optical Drive Cooling Fans Removing A Cooling FanInstalling A Cooling Fan Removing The Cooling-FanAssemblyInstalling The Cooling-FanAssembly Internal USB Memory Key OptionalReplacing The Internal USB Key PCIe Card HolderRemoving The PCIe Card Holder Installing The PCIe Card Holder Top Cover Lock Latch Installing The Top Cover Lock LatchOpening And Closing The PCIe Card Holder Latch Cable Retention Bracket Removing The Cable Retention BracketExpansion Card Installation Guidelines Installing The Cable Retention BracketExpansion Cards And Expansion-CardRisers Riser Converged expansion card 7.Replace the expansion-cardlatch expansion-cardriser 1 cage Removing Expansion-CardRisers expansion-cardslot chassis intrusion switch Installing Expansion-CardRisers GPU Card Installation GuidelinesInstalling A GPU Card Removing A GPU Card SD vFlash Card Replacing An SD vFlash CardRemoving The vFlash Media Unit Installing The vFlash Media Unit Internal Dual SD Module Removing The Internal Dual SD ModuleInstalling The Internal Dual SD Module Integrated Storage Controller Card Installing An Internal SD CardInternal SD Card Removing An Internal SD CardRemoving The Integrated Storage Controller Card Network Daughter Card Installing The Integrated Storage Controller CardRemoving The Network Daughter Card Installing The Network Daughter Card ProcessorsRemoving A Processor heat sink close-locksymbol Installing A Processor Power Supplies Hot Spare Feature Removing An AC Power SupplyInstalling An AC Power Supply Required Wires Wiring Instructions For A DC Power SupplyKit Contents Assembling And Connecting The Safety Ground WireAssembling The DC Input Power Wires Removing A DC Power Supply Installing A DC Power Supply Installing The Power Supply Blank System BatteryRemoving The Power Supply Blank Replacing The System BatteryHard-DriveBackplane Removing The Hard-DriveBackplane backplane power cable B backplane signal cablebackplane power cable A release tabscable retention bracket 5.SAS connectors on the backplaneSAS connector mini PERC SAS on the system boardcable retention bracket SAS connector on the system boardSAS connector on the backplane system boardhard-drivebackplane connectors backplane power cablesbackplane signal cable x16 hard-drivebackplanecable retention bracket 5.SAS connectors on the backplaneSAS connector on the system board system boardx8 hard-drivebackplane backplane power cablebackplane signal cable release tabsystem board backplane signal cable hard-drivebackplane connectorsbackplane power cable release tabcable retention bracket release tabs integrated storage controller card cable retention bracketsystem board 5.SAS backplanex24 hard-drivebackplane Installing The Hard-DriveBackplane Removing The Optional Hard-DriveBackplane Back pass-throughI2C cable Installing The Optional Hard-DriveBackplane Back Removing The Control Panel PowerEdge R720 Control Panel BoardInstalling The Control Panel PowerEdge R720 Removing The Control Panel PowerEdge R720xd Installing The Control Panel PowerEdge R720xd Removing The I/O Panel PowerEdge R720xd System Board Installing The I/O Panel PowerEdge R720xdRemoving The System Board f.internal dual SD module Installing The System Board h.cooling shroud i.power supplys d.internal USB key if installedf.all expansion-cardrisers g.cooling-fanassembly 5.Replace the following a.cable retention bracketTroubleshooting System Startup Failure Troubleshooting Your SystemSafety First-ForYou And Your System Troubleshooting External ConnectionsTroubleshooting A NIC Troubleshooting A Serial I/O DeviceTroubleshooting A Wet System Troubleshooting A Damaged System Troubleshooting Power Supplies Troubleshooting The System BatteryTroubleshooting Cooling Problems Troubleshooting Cooling Fans Troubleshooting System MemoryTroubleshooting An Internal USB Key Troubleshooting An SD CardTroubleshooting A Tape Backup Unit Troubleshooting An Optical DriveTroubleshooting A Hard Drive Troubleshooting A Storage Controller Troubleshooting Expansion Cards Troubleshooting ProcessorsIf the problem persists, see Getting Help Dell Embedded System Diagnostics Using System DiagnosticsDell Online Diagnostics When To Use The Embedded System DiagnosticsSystem Diagnostic Controls Jumpers And Connectors System Board Jumper Settings1J_PS2 2J_SATA_CD 3J_SATA_TBU 4J_BP0 5J_TBU System Board ConnectorsRiser 3 connector USB connector 6J PS1 7J IDSDM 8J NDC 9J RISER 3A 10J RISER 3B12J VIDEO REAR 13J COM1 14J IDRAC RJ45 15J CYC Backplane signal connector Disabling A Forgotten PasswordConnector ItemProcessor Technical SpecificationsExpansion slots using riser card Expansion BusMemory DrivesFront Connectors BackDrives InternalExpanded Operating Temperature Temperature Continuous Operation EnvironmentalTemperature Relative HumidityParticulate Contamination EnvironmentalGaseous Contamination LCD Messages System Error MessagesSystem Messages Viewing LCD MessagesError Code Error Code See Getting HelpError Code Error Code Error Code <location> Error Code<location> Error Code <location>Error Code Helpsee Getting Help Error CodeGetting Help Error Code Getting HelpError Code see Getting HelpError Code see Getting HelpError Code See Getting HelpError Code Error Code Warning Messages Diagnostic MessagesAlert Messages Getting Help Contacting Dell
Related manuals
Manual 11 pages 39.53 Kb Manual 11 pages 49.82 Kb

R720XD, R720 specifications

The Dell PowerEdge R720 and R720xd are powerful rack servers designed to deliver exceptional performance, reliability, and scalability for a wide range of data center applications. As part of Dell's 12th generation of PowerEdge servers, they come equipped with advanced features and technologies that cater to diverse workloads.

Both models are built on the Intel Xeon processor E5-2600 family, supporting dual-socket configurations. This allows for an impressive maximum memory capacity of up to 768 GB with 32 DIMM slots, enabling efficient handling of memory-intensive applications. The R720 and R720xd are designed with efficiency in mind, allowing organizations to optimize their resource utilization while maintaining high performance.

One of the most noteworthy features of the R720 and R720xd is the flexible storage options. The R720 can accommodate up to 16 2.5-inch drives, while the R720xd extends this capacity to 24 2.5-inch drives or 12 3.5-inch drives, greatly enhancing storage scalability. This flexibility is essential for businesses with growing data needs, allowing them to configure the server according to their specific requirements.

Both servers come with the iDRAC7 (Integrated Dell Remote Access Controller), which provides advanced management capabilities. iDRAC7 enables IT administrators to remotely monitor and control the server, simplifying the management of hardware functions and system updates. The optional Lifecycle Controller further streamlines server deployment and management, offering integrated systems management capabilities.

In terms of networking, the R720 and R720xd support a variety of network interface cards, including 1 GbE and 10 GbE options. This ensures that organizations can select the right networking capabilities for their specific workload and performance requirements.

Power efficiency is another significant characteristic of these servers. Equipped with Dell’s Energy Smart technologies, they can reduce power consumption and operating costs. Features like power capping and efficient fan control help achieve optimal thermal management in the data center.

In summary, the Dell PowerEdge R720 and R720xd are robust and versatile servers that offer exceptional performance for mission-critical applications. With their advanced processor support, memory capacity, flexible storage configurations, and comprehensive management features, they are well-suited for organizations looking to enhance their IT infrastructure.