Black Box LB303A manual Installation, Selecting a Site for the Equipment, DIN Rail Mounting

Page 10
Installation

Hardened VDSL Ethernet Extender

Installation

This chapter gives step-by-step installation instructions for the Hardened VDSL

Ethernet Extender.

Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

The ambient temperature should be between -34 to 74 degrees Celsius.

The relative humidity should be less than 95 percent, non-condensing.

Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards.

Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes of the equipment.

The power outlet should be within 1.8 meters of the product.

DIN Rail Mounting

Fix the DIN rail attachment plate to the back panel of the Hardened VDSL Ethernet Extender.

Installation: Place the Hardened VDSL Ethernet Extender on the DIN rail from above using the slot. Push the front of the Hardened VDSL Ethernet Extender toward the mounting surface until it audibly snaps into place.

Removal: Pull out the lower edge and then remove the Hardened VDSL Ethernet Extender from the DIN rail.

10

Image 10
Contents Order toll-free in the U.S. Call 877-877-BBOX Outside U. S. call Hardened VDSL Ethernet Extender LB303ACUSTOMER SUPPORT INFORMATION Mailing address Black Box Corporation, 1000 Park Drive, Lawrence, PAHardened VDSL Ethernet Extender 18. Servicio por personal calificado deberá ser provisto cuando Preface Installation Table of ContentsPreface Table of Contents Introduction SpecificationsIntroduction Product Overview Product FeaturesPacking List The Hardened VDSL Ethernet Extender AC to DC Power Adaptor and Power Cable optionalUSER’S MANUAL One-Channel Hardened VDSL Ethernet Extender VDSL Mode SettingsDIP switch PortsLED Indicators Front Panel & LEDsSelecting a Site for the Equipment InstallationDIN Rail Mounting Redundant DC Terminal Block Power Inputs Connecting to Power12VDC DC Jack Specifications Standards ESD Standard EN61000-4-2 Radiated FRI Standards EN61000-4-3