Accton Technology EH3016N, EH3008N manual Port and Cable Assignments, Straight-Through Crossover

Page 7

CheetaHub Power-3008N/3016N

Installation

Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.

Port and Cable Assignments

RJ-45 Port Description

RJ-45 (MDI-X) station ports can be attached to any devices which use a standard network interface (e.g., a workstation, server, bridge or router). RJ-45 (MDI) daisy- chain ports can be cascaded to a station port on similar networking devices (e.g., another hub or switch). Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10 Mbps connections or 100Ω Category 5 cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

Pin

Assignment

Assignment (Daisy-Chain

(Station Ports 1 - 8/16)

Port, other device)

 

1

Input Receive Data +

Output Transmit Data +

2

Input Receive Data -

Output Transmit Data -

3

Output Transmit Data +

Input Receive Data +

6

Output Transmit Data -

Input Receive Data -

4,5,7,8

Not Used

Not Used

Schematics for both straight and crossover twisted-pair cable are shown below.

 

Straight-Through

 

 

 

Crossover

 

(Hub)

(Adapter)

 

(Hub)

(Hub)

1

IRD+

1

OTD+

 

1

IRD+

1

IRD+

2

IRD-

2

OTD-

 

2

IRD-

2

IRD-

3

OTD+

3

IRD+

 

3

OTD+

3

OTD+

6

OTD-

6

IRD-

 

6

OTD-

6

OTD-

EMI Certification (ES3008N)

FCC Class B (USA)

Accton Technology Corporation Model Number: EH3008N

This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:

1.This device may not cause harmful interference, and

2.This device must accept any interference received, including interference that may cause undesired operation.

Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,

Quick Installation Guide

may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment into an outlet on a circuit different from the one which the receiver is connected to

Consult the dealer or an experienced radio/TV technician for help

You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

Note: In order to maintain compliance with the limits of a Class B digital device, Accton requires that you use a quality interface cable when connecting to this device. Changes or modifications not expressly approved by Accton could void your authority to operate this equipment. Suggested cable type is:

RJ-45: Unshielded or shielded (UTP/STP) cable – Category 3 or greater for 10Mbps connections, and Category 5 for 100Mbps connections.

Class B (Canada Department of Communications)

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Department of Communications.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la norme sur le matériel brouilleur: "Appareils Numérques", NMB-003 édictée par le ministère des Communications.

VCCI Class B Compliance (Japan)

CE Mark Declaration of Conformance (for EMI and Safety - Europe)

This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications:

EMC: EN55022(1988)/CISPR-22(1985)

class B

IEC1000-4-2(1995)

4kV CD, 8kV AD

IEC1000-4-3(1995)

3V/m

IEC1000-4-4(1995)

1kV - (power line), 0.5kV - (signal line)

IEC1000-4-6(1995)

3Vrms

This product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC.

8

9

Image 7
Contents CheetaHub Power-3008N/3016N Quick Installation Guide International Headquarters USA Headquarters CheetaHub Power-3008N/3016NContents Making a Connection via an RJ-45 Station Port Quick Installation Guide Connecting the Hub SystemMounting the Hub Stacking Hubs on a Flat SurfaceVerifying System Operation Powering On the HubQuick Installation Guide Verifying Port Status State IndicationProduct Specifications CheetaHub Power-3008N/3016N Quick Installation GuideTroubleshooting Straight-Through Crossover Port and Cable AssignmentsEMI Certification ES3008N Quick Installation Guide Safety Compliance CheetaHub Power-3008N/3016N EMI Certification EH3016NWarranty