Lathem 1200 Series user manual Changing the Motor

Page 10

1200 Series User’s Manual

Changing the Motor

Figure 6

1.Unplug cord from wall outlet.

2.Remove type section from main frame (see “Replacing the Type Section”).

3.Figure 6 shows a close-up of cam block terminal.

4.Disconnect Motor Wire Leads – 6.1 by turning each Screw – 6.2 one-quarter of a turn counterclockwise.

5.Remove the Motor Clutch – 6.3 from its shaft. The shaft has LEFT HAND threads – remove clutch by turning clockwise.

6.Hold Motor Bracket – 6.4 and loosen Motor Mounting Screws – 6.5. Remove and retain screws and bracket from old motor.

7.Install motor clutch on new motor. Turn counterclockwise to tighten. DO NOT OVERTIGHTEN OR BEND – YOU MAY DAMAGE INTERNAL MOTOR GEARS.

8.Install new motor.

9.Plug cord back in wall outlet, and reset the time.

8

Image 10
Contents Series Lathem Time Corporation Contents Ordering Accessories Http//shop.lathem.comSetting the Time Raise the Type SectionSet the Time on the Type Wheels Set the Time on the Clock Face Changing the Ribbon Replacing the Type Section Remove Type Section Retaining RingChanging the Motor Warranty One-Year Limited WarrantyOMTR12-0603