Samsung SP-M220S RS232C Command Table, Communication Format Complies with the RS232C Standard

Page 48

5-2 RS232C Command Table

Communication Format (Complies with the RS232C Standard)

Baud rate : 9,600 bps

parity : None

Data bits : 8, stop bit : 1

Flow Control : None

Serial Communication Protocol

1.Command Packet Structure [7bytes]

0x08

0x22

cmd1

cmd2

cmd3

value

CS

 

 

 

 

 

 

 

A command packet consists of 7 bytes in total.

The two bytes 0x08 and 0x22 signify that the packet is for serial communication.

The following 4 bytes represent a pre-defined command that can be defined by the user.

The last byte is the checksum which checks the validity of the current packet.

Header [2 Byte]: Pre-defined values fixed to 0x08 and 0x22.

Cmd1 [1 Byte]: The first value of the code defined in the command list (Hexadecimal)

Cmd2 [1 Byte]: The second value of the code defined in the command list (Hexadecimal)

Cmd3 [1 Byte]: The third value of the code defined in the command list (Hexadecimal)

Value [1 Byte]: Input parameter for the command (Default: 0) (Hexadecimal)

CS [1 Byte]: Checksum (the 2’s complement of the sum of all the values except for the CS value.)

2.Response Packet Structure [3 Bytes] 1. Success

0x03

2.Fail

0x0C

0xF1

0x030x0C0xFF

When the received packet from an external device has a valid value, a Success packet is sent. Otherwise, a Fail packet is sent.

A Fail packet is sent if:

The received packet length is not equal to 7 bytes.

The 2 byte packet header value is not equal to 0x08, 0x22.

The check sum is incorrect.

Failure detection by an external device

An external device classifies the packet as Fail if it does not receive a Success packet within 100ms.

5-2

More Information

Image 48
Contents LCD Projector Table Of Contents Using this Manual Before You StartIcons used in this manual Copyright NoticeCare and Maintenance Cleaning the Surface and the LensSafety Precautions Icons used for safety precautionsPower Related Meaning of SignsInstallation Related Usage Related Major Safety Precautions Major Safety Precautions Installation and Connection Package ContentsInstalling the Projector Leveling with Adjustable Feet Zoom and Focus Adjustment Screen Size and Projection Distance Installation and Connection Lamp Replacement Lamp Replacement ProcedureReplacing and Cleaning the Filter Ventilation openingsAir intake vent Rear Side Supported Display Modes PC Timing D-Sub/HDMIFormat Resolution Scan AV Timing D-SubAV Timing Hdmi AV Timing Video Connecting the Power Connecting with a PC and Setting up the PC Setting up the PC EnvironmentConnecting with a PC Connecting a PC using an HDMI/DVI cable Connecting an HDMI-Compatible Device Connecting an AV device using a D-Sub cable Connecting an AV device with Component output Connecting using a Video cable Connecting an External Speaker Kensington Lock slot Locking the productUsing Product FeaturesFront, Upper Name DescriptionRemote Control Install ButtonLED Indications LED IndicationsStatus Lamp Stand by Clearing Indicator Problems Classifica State Measures TionUsing the Screen Adjustment Menu OSD On Screen Display InputPicture Menu SUB-MENUGame mode, the text in still pictures will appear unnatural Overscan is not supported in AV modes Setup Usage Option Troubleshooting Before Requesting Service Screen Specifications ModelMore Information RS232C Command Table Communication Format Complies with the RS232C StandardSerial Communication Protocol Command Table Control Item CMD1 CMD2 CMD3 ValueControl Item CMD1 CMD2 CMD3 Value IRE/NOR Picture Horizontal Continuous ECO ไทย Control Item CMD1 CMD2 CMD3 Value Contact Samsung Worldwide North AmericaLatin America EuropeCIS Asia PacificMiddle East & Africa Correct Disposal Europe only Correct disposal of batteries in this product Europe onlyMore Information