System Overview
3.2.6.1 HVPS (High Voltage Power Supply)
Transfer High Voltage (THV+)
-Input Voltage : 24 V DC 15%
-Output Voltage : MAX +5.0KV 5 %,(Duty Variable, no loading )
-Input contrast of the Voltage stability degree : under 3 % (fluctuating input 21.6V~26.4V)
Loading contrast : 3 % or less
-Output Voltage Rising Time : 100 ms Max
-Output Voltage Falling Time : 100 ms Max
-Fluctuating transfer voltage with environmental various : +650 V~ 5 KV
-Environment Recognition Control Method : The
-Output Voltage Control Method : Transfer Output Voltage is outputted and controlled by changing Duty of THVPWM Signal.
Charge Voltage (MHV)
-Input Voltage : 24 V DC 15%
-Output Voltage :
-Output Voltage Rising Time : 50 ms Max
-Output Voltage Falling Time : 50 ms Max
-Output Loading range : 30 M ~ 1000 M
-Output Control
Cleaning Voltage
-The (+) Transfer Voltage is not outputted because the THV PWM is controlled with high.
-The
-The output fluctuation range is big because there is no Feedback control.
-Input Voltage : 24 V DC 15%
-Output Voltage :
-Output Voltage Rising Time : 100 ms Max
-Output Voltage Falling Time : 100 ms Max
Developing Voltage (DEV)
-Input Voltage : 24 V DC 15%
-Output Voltage:
-Output Voltage Fluctuation range: PWM Control
-Input contrast of the output stability degree : 3 % or less
Loading contrast : 3 % or less
-Output Voltage Rising Time : 50 ms Max
-Output Voltage Falling Time : 50 ms Max
-Output Loading range : 10M ~ 1000 M
-Output Control Signal
Samsung Electronics
Service Manual