Environmental
Table 6. Environmental Specifications
  | Operating  | |
Temperature*  | 0 to +65 °C  | |
Humidity  | 
  | 
  | 
to 93% RH max @40 ºC,  | 
  | |
  | per IEC   | 
  | 
  | 
  | 
  | 
Altitude  | 
  | 
  | 
Tested per IEC   | 16,000 ft. (4.8 km)  | 58,000 ft. (17.7 km)  | 
  | 
  | 
  | 
Vibration (random)  | 
  | 
  | 
(Operating/non-  | 0.02 g2/Hz at   | |
operating)  | axis, per IEC   | |
  | 
  | 
  | 
Mechanical Shock  | 
  | 
  | 
50 g with 11 ms duration, half sine wave, 3  | ||
  | shocks on each of 6 surfaces, per IEC   | |
  | test Ea.  | 
  | 
  | 
  | 
  | 
*The EL display will function at operating survival temperatures 
Reliability
The display mean time between failure (MTBF) is demonstrated to be greater than 30,000 hours at 25 °C ambient with a 90% confidence level.
Safety and EMI Performance
The display will not inhibit the end product from obtaining UL1950, CSA950, or IEC 
When housed in a suitable enclosure, the display is capable of being operated in a final product that complies with CISPR 11 level B, IEC 
10