Power Supply

CAUTION: Use only the power adapter supplied with the Dome E2c display unit; Ault MW122KA1223F52.

Category

Characteristic Item

Specification

 

 

 

Power input

Voltage selection

Auto-ranging

requirements

Voltage

100 – 240V AC

 

 

Current

2.0 A

 

Frequency

50 to 60 Hz

 

 

 

Power output

Voltage

12 V DC ±5%

requirements

Current

10.0 A (120 W)

 

 

 

 

Physical

Size

228.6 mm x 76.2 mm x 50.8 mm

 

 

(9 in x 3 in x 2 in)

 

Weight

1.3 kg (2.75 lb)

 

 

 

Reliability

Characteristic item

Specification

 

 

Display

MTBF >50,000 hours

 

 

Backlight

MTBF >40,000 hours

 

 

Environment

Characteristic item

 

Specification

 

 

 

EMI shielding

 

No emission of low-level radiation

 

 

 

Temperature

operating

5° C to 40° C

 

storage

–20° to 60° C

 

 

 

Humidity

operating

20% to 90% Relative Humidity

 

 

(non-condensing)

 

storage

<70% Relative Humidity (non-condensing)

 

 

 

Dome E2c Specification 13

Image 23
Contents User’s Guide Dome E2c DisplayPlanar Systems, Inc. All rights reserved Contents Product Information Intended use Symbol explanationsSafety tips Safety precautionsPreventing fire and injury Unpacking and handling tipsCleaning the display Disposal information Shipping/storing the displayQuick reference System Requirements About the DisplayDisplay Components Tilt range Height range Display PositionsStand cable cover Desk Stand FeaturesTips Installing the DisplayTo install the display controller Install the Display ControllerTo connect the cables Connect the Video and Power CablesTo configure the display Install the Display DriverTo install the driver To set brightness Adjust Display PropertiesTo use a dual-display configuration To set the display orientation Appendix Problem Possible Cause Solution TroubleshootingCategory Characteristic Item Specification Dome E2c SpecificationEnvironment Power SupplyReliability Video Timing Video ModesConnector Ports LED Indication Lights Reset left and LED on connector plateTo remove the AX1 driver Display Driver RemovalPower Management Brightness, display IndexCanada, European Union, United States Regulatory ComplianceFax + 358 9 420 EU Declaration of Conformity for Medical Application FCC Compliance Statement Korea AustralianChina JapanSummary Standard WarrantyStandard Warranty Return Procedure Limitation of Implied Warranties Summary Limitations and Exclusions of Dome DisplaysEffect of Local Law Exclusion of DamagesMedicalsales@planar.com Medicalsupport@planar.com