INSTALLATION MODE

GB

Installation Mode

Installation Mode VER -.--

Network Initial

>>>

Temperature Error

 

This LCD monitor allows you to set up the following:

SETTING PROCEDURE

1 . Press and hold the GREEN button on the remote control for 5 seconds. (Installation Mode will appear)

2.Use the 5 or 6 button to highlight each option, use the 1 or 2 button to adjust each option. Press the MENU button to exit the mode.

On Program

Select ON program using the 5 or 6 button, select the start up position using the 1 or 2 buttons.

(Off/ AV1/ RGB/ AV2/ AV3/ PC/ DVI or Network)

Max Volume

Select Max volume using the 5 or 6 button, use the 1 or

2buttons to set the maximum volume required.

Winter mode

This Function can be activated when the LCD monitor is used during cold temperature conditions, approximately 38˚F/ 4˚C or below to maintain picture performance.

Using the 5 or 6 button select winter mode, once highlighted you can select ON or OFF by pressing the 1 or 2 button. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function.

When in winter mode, power consumption is higher than normal standby consumption. This is entirely due to the operation of heating circuitry. We strongly recommend to turn off Winter mode when the ambient temperature is above 38˚F/ 4˚C.

RC inhibition

You can prevent unwanted remote control operation by selecting RC Inhibition.

Select using the 5 or 6 button. Press the 1 or 2 button to select On or Off.

To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF.

Child Lock

You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor.

Select using the 5 or 6 button. Press the 1 button to select On or OFF. The ‘Child Lock’ OSD will appear if buttons are pressed when child lock is On.

Standby operates normally when childlock is set “On”.

Address

Set the address for the LCD monitor (0 - 999).

Baud rate

Select Baud rate using the 5 or 6 button. To set transmission speed RS232 or LD-NET communication for 19200 or 9600 Baud rate by pressing the 1 or 2 button.

Panel Protect

Select Panel Protect using the 5 or 6 button, once highlighted you can select ON or OFF by pressing the 1 or 2 button.

AV Auto shut off

Select AV Auto Shut Off using the 5 or 6 button, once high- lighted you can select On or Off by pressing the 1 or 2 button.

LED Light setting

Select LED Light setting using the 5 or 6 button, once high- lighted you can select On or Off by pressing the 1 or 2 button.

DCR

Select DCR using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button.

Network Initial

This function automatically installs the IP Address, Subnet, Gateway and DNS information.

Temperature Error

This function can record times for abnormal temperture.

IP Address / Subnet / Gateway / DNS

These 4 items display the LD-Net information. If LD-NET is NOT connected, all the items would be displayed as “000000000000”.

Disconnecting the mains supply before exiting Installation Mode will cancel the following features On program, RC inhibition, Address and Baud Rate.

10

Image 10
Contents Monitor de LCD LCD Monitor Moniteur daffichage à cristaux liquidesEspañol Página Important UK only Safety PrecautionsInstallation and Use Additional for North America and CanadaServicing ServicingImportant recycling information Decloration of Conformity North America and Canada AC Power Cord RequirementEnd-User License Mains Connection InstallationConnections Remote Control Menu Operation Switching into/from standby modeControls and Menus Picture menuSound menu Setup menuMenu Operation Time menuPC Adj. menu Setting Procedure Installation ModeInstallation Mode DCROperation Selecting of picture sizePIP1, PIP2, POP or OFF mode PIP1 mode OFF mode PIP2 mode POP modePIP/POP Operation Operation in Text Mode Teletext OperationSpecification Helpful hints PC/DVI-D / Component Signal Support Timing List RS232C Command Tables RS232C Command Tables Part No KA6P1P0423-C N5VV