Sanyo CE-52LH1R instruction manual Safety Precautions, Installation and Use, Important UK only

Page 2

GB

SAFETY PRECAUTIONS

GB

CAUTION: Please read and retain for your safety. This unit has been designed and manufactured to assure your personal safety, but improper use can result in potential electric shock or fire hazards. In order not to defeat the safeguards incorporated in this monitor observe the following basic rules for its installation, use and servicing.

Installation and Use

Do not allow anything to rest on the power cord. Do not locate this LCD monitor where the cord will be damaged by people walking on it.

Do not overload wall outlets and extension

cords as this can result in fire or electric shock.

A suitable socket outlet must be provided

near to the monitor and shall be easily accessible.

Do not place this LCD monitor near any heat sources such as radiators, heaters, stoves and other heat-generating products (including amplifiers).

Do not place your LCD monitor on an unstable stand, shelf or table. Serious injury to an individual, and damage to the LCD monitor may result if it should fall. Your sales person can recommend an approved wall mounting kit. A special wall mounting kit is available for this model.

This LCD monitor should be operated only from the type of power source indicated on the monitor or as indicated in the Operating Instructions. If you are not sure of the type of power supply, consult your sales person or your local power company.

For added protection it is strongly recommended that this LCD monitor has its mains supplied via an approved earth fault protection device.

WARNING: To prevent injury the LCD monitor must be securely attached to the wall in accordance with the manufacturers installation instructions.

IMPORTANT:

This product must be earthed

This unit is not disconnected from the mains unless the mains lead is unplugged. The installer must make sure that the waterproof inline coupler is easily accessible.

Do not use immediately after moving the LCD monitor from a low temperature to a high temperature environment, as this causes condensation, which may result in fire, electric shock, or other hazards. Before cleaning, unplug the monitor from the wall socket.

Do not mount near an open flame source. Open flames must never be used near this LCD monitor.

This LCD monitor should not be built in or enclosed in any way, heat build up will reduce the life of the monitor.

This LCD monitor should have a minimum distance of 5cm away from the wall and the monitor should have 10cm distance around the top and sides.

10cm

5cm

10cm

10cm

Always mount using recommended and substantial fixtures and fittings.

The rear finned section around the cabinet functions as a heat sink, removing heat away from the monitor. The external surface of the cabinet (finned area) must not be covered or the airflow restricted in anyway by enclosing the LCD monitor.

Do not apply liquid cleaners or aerosol cleaners directly onto the LCD monitor. Use a damp cloth for cleaning.

ADDITIONAL FOR NORTH AMERICA AND CANADA:

This monitor must NOT be permanently mounted to the building structure. It must be mounted in such a way that it can be removed using basic tools.

The power supply cord must NOT be attached to the building sur- face. The power supply cord must NOT be routed through walls, ceiling, floors, or other similar openings in the building structure. The power supply cord MUST be positioned so as to prevent physical damage.

Important: (UK only)

THIS PRODUCT MUST BE EARTHED

This equipment is fitted with an approved mains lead and an approved non rewireable UK mains plug. To change a fuse in this type of plug proceed as follows:

1.Remove the fuse cover and fuse.

2.Fit a new fuse which should be a BS1362 13 Amp A.S.T.A. or BSI approved type.

3.Ensure that the fuse cover is correctly refitted.

If the fuse cover is lost or damaged the plug must NOT be used but replaced with a serviceable plug.

If the fitted plug is not suitable for your socket outlets, it should be cut off and an appropriate plug fitted in its place. If the mains plug contains a fuse, this should have a rating of 13 Amp, ensure the fuse cover is correctly fitted. If a plug without a fuse is used, the fuse at the distribution board should not be greater than 13 Amp.

Note: The severed plug must be destroyed to avoid a possible shock hazard should it be inserted into a 13 Amp socket elsewhere.

The wires in this mains lead are coloured in accordance with the following code:

Blue -------

>

Neutral

Brown ----

>

Live

Green and Yellow

----> Earth

1.The Blue wire must be connected to the terminal which is marked with the letter “N” or coloured BLACK.

2.The Brown wire must be connected to the terminal with the let- ter “L” or coloured RED.

3.The Green and Yellow wire must be connected to the terminal which is marked with the letter “E” or coloured GREEN or GREEN and YELLOW.

Before replacing the plug cover, make certain that the cord grip is clamped over the sheath of the lead - not simply over the wires.

Do not attempt to bypass the safety purpose of the grounding type plug.

THIS UNIT IS NOT DISCONNECTED FROM THE MAINS UNLESS THE MAINS LEAD IS UNPLUGGED.

THE INSTALLER MUST MAKE SURE THE MAINS LEAD IS EASILY ACCESSIBLE.

2

Image 2
Contents Español Página LCD Monitor Moniteur daffichage à cristaux liquidesMonitor de LCD Important UK only Safety PrecautionsInstallation and Use Additional for North America and CanadaImportant recycling information ServicingServicing End-User License AC Power Cord RequirementDecloration of Conformity North America and Canada Connections InstallationMains Connection Remote Control Menu Operation Switching into/from standby modeControls and Menus Picture menuSound menu Setup menuMenu Operation Time menuPC Adj. menu Setting Procedure Installation ModeInstallation Mode DCROperation Selecting of picture sizePIP/POP Operation PIP1 mode OFF mode PIP2 mode POP modePIP1, PIP2, POP or OFF mode Operation in Text Mode Teletext OperationSpecification Helpful hints PC/DVI-D / Component Signal Support Timing List RS232C Command Tables RS232C Command Tables Part No KA6P1P0423-C N5VV