Industry Sector, IA&DT

3.3Previous configuration

The following requirements are to be met with the help of the Panel.

-It is now possible to operate the ink mixing station via the Panel as well.

-The fill levels of the tanks and of the container are to be indicated as bars and also as numerical value.

-The movement of the mixer motor is to be represented graphically.

-The target quantities are to be entered using the panel.

-The minimum and maximum fill levels of the three tanks can be specified on separate tank screens.

-The Panel can also be used to change operating modes.

-The finished color mixtures are saved as recipe in the Panel.

-The fill levels are monitored and alarms are generated in the event of danger.

-A password must be entered in order to operate the ink mixing station.

-The SIMATIC S7-300 controller communicates with the TP700 Comfort Panel and monitors it via

PROFINET.

3.4Expanded configuration and task

On the programming device, the STEP 7 Professional V11 configuration software and WinCC Advanced V11 are used to create an additional process visualization for an operator PC.

The operator PC communicates with the operator panel via tags using an HMI HTTP connection. The

S7-300 controller is accessed solely via the operator panel.

The value of a tag in the memory area (address) of the controller is read by the operator panel and transferred via an HMI HTTP connection to the operator PC.

The ink mixing station is remotely monitored and remotely operated using the visualization and the operating screens.

SCE Training Curriculum

Page 10 of 48

To be used only at Educational and R&D Facilities

TIA Portal Module 090-020, Edition 03/2013

 

Unrestricted / © Siemens AG 2013. All Rights Reserved

SCE_EN_090-020_R1209_ WinCC Advanced Runtime Services

 

 

 

 

 

Image 10
Contents SCE Training Curriculum Suitable SCE trainer packages for these training curriculums Professional V11 TIA Portal V11 programming software Learning objective PrefaceRequirements Required hardware and software Simatic S7-300 automation system Professional V11 TIA Portal V11 programming softwareOperator control and monitoring with WinCC PC for configuration Project description Hardware configurationTP700 as HMI device Station description Tank Previous configuration Expanded configuration and taskInserting an Operator PC in the Ink Mixing Station project Totally Integrated Automation PortalLoading and re-saving a project template Click Open project view Industry Sector, IA&DT Industry Sector, IA&DT Industry Sector, IA&DT New PC-SystemAdvancedyou added is opened in the device view Industry Sector, IA&DT Industry Sector, IA&DT Industry Sector, IA&DT Configuring on the operator PC Simatic HMI Http connection Creating a Simatic HMI Http connection Tags on the PC-SystemAdvanced Configuring the overview screen Default tag table of PC-SystemAdvancedIndustry Sector, IA&DT Industry Sector, IA&DT Save the project Starting the PC-SystemAdvanced in Runtime Trend view of the ink mixing station Trend View 1 screenUnder Source settings, select the tag Panel1volumeTank1 Layout, change the Position & size Save the project Industry Sector, IA&DT Trend view in runtime Access via Html pages Remote Control of the TP700 Comfort with Sm@rtOptionsSecurity concept for the Sm@rtServer Sm@rtServer Runtime Service Sm@rtClient application on the PC Industry Sector, IA&DT Click Remote Control Sm@rtClient via Web browserClick Start Sm@rtClient Industry Sector, IA&DT Industry Sector, IA&DT Create the buttons for the screen selection Sm@artClient view in Runtime Configuring the Html browser HTMLBrowser from the ControlsLayout, change the Position & size Html browser in Runtime