3.2Station description

Tank 1

 

Tank 2

 

Tank 3

 

 

 

 

 

Auto-Man

START T1 supply

T1 drain

T2 supply

T2 drain T3 supply

T3 drain

Container Motor

An ink mixing station is controlled using a SIMATIC S7-300 in automatic or in manual mode. In the 'Automatic' mode, the three tanks are filled using a two-point control mechanism.

At minimum fill level the supply valve of the corresponding tank is opened automatically and only closed once the maximum fill level is reached.

The preset program is run when the Start button is pressed.

First, the drain valves are opened and the corresponding target quantities are filled into the container from the separate tanks.

After closing the drain valves, the mixer motor is started.

At the end of the mixing period and after a short rest period, the drain valve of the container opens and the finished color mixture is drained.

The start function is enabled as soon as the container is empty. The start button lamp is lit and a new color mixture can be started.

In "Manual" mode, the automatic drain is terminated; all valves and the mixer motor can then be operated manually.

The lamps in the buttons for manual operation are lit.

SCE Training Curriculum

Page 9 of 48

To be used only at Educational and R&D Facilities

TIA Portal Module 090-020, Edition 03/2013

 

Unrestricted / © Siemens AG 2013. All Rights Reserved

SCE_EN_090-020_R1209_ WinCC Advanced Runtime Services

 

 

 

 

 

Image 9
Contents SCE Training Curriculum Suitable SCE trainer packages for these training curriculums Professional V11 TIA Portal V11 programming software Preface Learning objectiveRequirements Required hardware and software Professional V11 TIA Portal V11 programming software Simatic S7-300 automation systemOperator control and monitoring with WinCC Project description Hardware configuration PC for configurationTP700 as HMI device Station description Tank Expanded configuration and task Previous configurationTotally Integrated Automation Portal Inserting an Operator PC in the Ink Mixing Station projectLoading and re-saving a project template Click Open project view Industry Sector, IA&DT Industry Sector, IA&DT Industry Sector, IA&DT New PC-SystemAdvancedyou added is opened in the device view Industry Sector, IA&DT Industry Sector, IA&DT Industry Sector, IA&DT Configuring on the operator PC Simatic HMI Http connection Creating a Simatic HMI Http connection Tags on the PC-SystemAdvanced Default tag table of PC-SystemAdvanced Configuring the overview screenIndustry Sector, IA&DT Industry Sector, IA&DT Save the project Starting the PC-SystemAdvanced in Runtime Trend View 1 screen Trend view of the ink mixing stationUnder Source settings, select the tag Panel1volumeTank1 Layout, change the Position & size Save the project Industry Sector, IA&DT Trend view in runtime Remote Control of the TP700 Comfort with Sm@rtOptions Access via Html pagesSecurity concept for the Sm@rtServer Sm@rtServer Runtime Service Sm@rtClient application on the PC Industry Sector, IA&DT Sm@rtClient via Web browser Click Remote ControlClick Start Sm@rtClient Industry Sector, IA&DT Industry Sector, IA&DT Create the buttons for the screen selection Sm@artClient view in Runtime HTMLBrowser from the Controls Configuring the Html browserLayout, change the Position & size Html browser in Runtime