Transition Networks FD-CD-01(SM) warranty Standards, Case dimensions, Environment, FD-CD-01SM

Page 1
Warranty
Power Supply Requirements

MEDIA CONVERTER TECHNICAL SPECIFICATIONS

Standards

ANSI X3T12 FDDI

 

Case dimensions

4.7" x 3.0" x 1.0"

(119mm x 76mm x 25mm)

Environment

Temperature:

0-40°C (32° to 104° F )

 

Humidity

10-90%, non condensing

 

Altitude

0-10,000 feet

Lifetime

Replace power supply with only the equivalent input

rating (see below) and output rating (regulated 12VDC @1.5 A).

TN PN

Requirement

Location

3507

240 volts, 50 hertz

United Kingdom

3342

230 volts, 50 hertz

Europe

3340

120 volts, 60 hertz

USA/Canada/Mexico

3346

100 volts, 50-60 hertz

Japan

3511

240 volts, 50 hertz

Australia

3537

(with power cord: 3522)

South Africa

Minneapolis, MN 55344 USA

FDDI/CDDI Media Converters

FD-CD-01, FD-CD-01(SM)

USER’S GUIDE

The TRANSITION Networks Ethernet™ CDDI to FDDI media converters connect CDDI unshielded twisted pair cable to FDDI multimode OR to FDDI singlemode fiber-optic cable. Media converter models are selected according to the fiber mode required at the site. Both multimode fiber (FD-CD-01) and singlemode fiber (FD-CD-01(SM)) media converters use a standard SC connector. Both media converters function in half-duplex mode or, when connected to devices capable of full-duplex connectivity, in full-duplex mode. An MDI/MDI-X switch allows straight-throughtwisted-pair cable to be used for crossover CDDI connections.

NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.

CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.

FD-CD-01

Provides an RJ-45 twisted pair CDDI connector and an RX (receive) and TX (transmit) SC FDDI connector to multimode fiber-optic cable.

 

X-MDI

MDI

 

Input

 

FD-CD-01

CDDI

12V DC

FDDI to CDDI

 

FDDI

FD-CD-01

UTP

Multimode Fiber

Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.

Compliance Information

UL Listed

FD-CD-01(SM)

Provides an RJ-45 twisted pair CDDI connector and an RX (receive) and TX (transmit) SC FDDI connector to singlemode fiber-optic cable.

 

X-MDI

MDI

 

Input

 

FD-CD-01(SM)

CDDI

12V DC

FDDI to CDDI

FDDI

Singlemode

FD-CD-01(SM)

UTP

Singlemode Fiber

C-UL Listed (Canada) CISPR/EN55022 Class B

Status LEDs on the connector side of the media converters provide the following information:

FCC Regulations

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.

Canadian Regulations

This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.

Copyright Restrictions

Power Illuminated green LED indicates connection to external AC power.

SDF Signal Detect/Fiber: Steady green LED indicates fiber port is connected to device.

SDC Signal Detect/Copper: Steady green LED indicates RJ-45 port is connected to device.

RXC Receive/Copper: Flashing green LED indicates packets are seen on RJ-45 port.

RXF Receive/Fiber: Flashing green LED indicates packets are seen on fiber port.

CDDI Connector

TX RX Power

SDF

SDC

 

RXC

 

 

 

 

 

RXF

 

 

 

 

Fiber

 

10BASE-T

 

 

 

UTP/STP Power

FDDI Connector

SDF

SDC

RXC

RXF

© 1997 TRANSITION Networks.

All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.

Trademark Notice

NOTE: Since the FDDI/CDDI protocol passes a “token” across the entire FDDI/CDDI ring, the RXC/RXF LEDs are continuously illuminated during normal operation.

All registered trademarks and trademarks are the property of their respective owners.