Hach sc100TM installation manual Section Installation, Customer Supplied Items

Page 5

Section 3

Installation

DANGER: Only qualified personnel should conduct the installation tasks described in this section of the manual.

Figure 3-1 Components of a Basic System

1

sc100

2

5

4

6

3

7

8

9

10

1.

Controller

6.

Lock washer, ¼-inch I.D. (4), Cat. No. 8H1336

 

 

 

 

2.

Mounting foot for panel mounting (2),

7.

Flat washer, ¼-inch I.D. (4),

 

Cat. No. 1000B4F3222

 

Cat. No. 8H1346

 

 

 

 

3.

Bracket for panel and pipe mounting,

8.

Pan head screws (4), M6 x 1.0 x 20 mm,

 

Cat. No. 1000C4F3217-101

 

Cat. No. 5867400

 

 

 

 

4.

Gasket for panel mounting, rubber,

9.

Pan head screws (4), M6 x 1.0 x 100 mm,

 

Cat. No. 1000A4F3249-101

 

Cat. No. 5867500

 

 

 

 

5.

Hex nut, M6 (4), Cat. No. 5867300

10.

Pan head screws (4), M6 x 1.0 x 150 mm,

 

 

 

Cat. No. 5867600

 

 

 

 

Table 3-1 Customer Supplied Items

Item

14-AWG wire for electrical power connections in conduit or 115 or 230 V ac power cord plus a NEMA 4X-rated strain relief

High-quality, shielded instrumentation cable for connecting the analog outputs plus a NEMA 4X-rated strain relief.

Mounting hardware for the sensor (available from the manufacturer, order separately). See the sensor manual.

Sun shield for mounting configurations where the sun strikes the front of the display. See Figure 3-7 on page 8.

Common hand tools

5

Image 5
Contents Hach sc100 Controller Table of Contents Section Specifications Precautionary Labels Safety InformationGeneral Information General Product InformationCustomer Supplied Items Section InstallationController Dimension Illustrations Mechanical InstallationInstallation Panel Mount Cut-out Dimensions Sun shield Hole pattern for mounting controller Installation Using the Optional Sun ShieldSun Shield Kit Components Vertical or Horizontal Pipe Mounting the Controller Installation Mounting the Controller10 Panel Mounting the Controller Installation Using a Power Cord Electrical InstallationInstallation in Conduit Power cord strain relief Conduit strain relief Wiring for Power at the Controller14 Wiring Connections Power Wiring Information15 Local Disconnect for Power Cord Disconnect Power Alarms and RelaysConnecting the Relays Output Connections at Terminal Block J6 Installation Connecting the Analog OutputsRecorder Wires Circuit Board Position Modify the controller for sensor hard-wiring as follows Connecting/Wiring the Sensor CableWiring the Sensor at Terminal Block J5 Terminal Number Terminal Designation Wire Color20 Hard-wiring the sensor Connecting the Optional Digital Output21 Network Card Position in the Controller Network Connections at Terminal Block J1Cleaning the Controller Section MaintenanceReplacement Items Replacement PartsAccessories Cat. NoTechnical and Customer Service U.S.A. only Section How to OrderA. Customers Information RequiredUnited States Section Repair ServiceCanada Latin America, the Caribbean, the Far East,Limitation of Remedies Limited WarrantyLimitations Compliance Information Product SafetyImmunity EmissionsAdditional Emissions Standard/s include FCC Part 15, Class a LimitsCompliance Information Index Hard-wired electrical applications

sc100TM specifications

The Hach sc100TM is a versatile and reliable device designed for monitoring and controlling water quality in various applications. Its robust features make it an essential tool for environmental scientists, water treatment facilities, and industrial processes. The sc100TM is equipped with a user-friendly interface that allows for easy navigation and configuration, ensuring quick implementation in various settings.

One of the standout features of the sc100TM is its multi-parameter capability. This device is designed to monitor a range of water quality parameters, including pH, dissolved oxygen, turbidity, and temperature, among others. This flexibility allows users to conduct comprehensive water quality assessments without the need for multiple devices, thereby reducing costs and maximizing efficiency.

The sc100TM employs advanced digital sensor technology that ensures high accuracy and reliability in readings. These sensors are designed to provide consistent performance even in challenging environments. The device is also compatible with a wide range of Hach sensors, enabling users to customize their monitoring solutions based on specific requirements.

In addition to its measurement capabilities, the sc100TM features built-in data logging and reporting functions. This allows users to track water quality trends over time, facilitating informed decision-making and compliance with regulatory standards. The data can be easily exported for further analysis or reporting, making it an essential companion for environmental monitoring and compliance activities.

Connectivity is another critical aspect of the sc100TM. With options for wireless data transmission, users can access real-time data remotely, promoting better monitoring and quicker response to any changes in water quality. This feature is particularly beneficial for facilities that require constant monitoring, as it enables quick interventions when necessary.

Another significant advantage of the sc100TM is its durability and design. Constructed to withstand harsh operating conditions, the device is both weatherproof and suitable for various industrial environments. Its compact design also allows for easy installation in tight spaces, making it adaptable to different setups.

In summary, the Hach sc100TM sets itself apart as a powerful tool for water quality monitoring. With its multi-parameter capabilities, advanced sensor technology, comprehensive data logging, and connectivity features, it provides users with the capability to maintain compliance and enhance water quality management strategies effectively. Whether in a laboratory or a field setting, the sc100TM is designed to meet the demands of modern water quality monitoring.