DC Power Supply Precautions

The following precautions must be observed when installing the chassis model with an internal DC power supply.

1.Check nameplate ratings to ensure there is no overloading of supply circuits that could effect overcurrent protection and supply wiring.

2.In addition, the following must be observed:

a.Connect the equipment to a 35 to 50 VDC power source that is electrically isolated from the alternating current source. The 35 to 50 VDC power source is connected to a SELV DC source.

b.Route input wiring to terminal block and secure in such a manner that it is protected from damage and stress. Do not route wiring past sharp edges or moving parts.

c.Incorporate a readily accessible disconnect device, with a 3mm minimum contact gap in the fixed wiring.

3.Reliable Earthing of this equipment must be maintained. Particular attention should be given to supply connections when connecting to power strips, rather than direct connections to the branch circuit.

IMC Networks Technical Support

Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);

+32-16-550880 (Europe)

Fax: (949) 465-3020

E-Mail:techsupport@imcnetworks.com

Web: www.imcnetworks.com

5

Image 8
Contents IE-ModeConverter Warranty FCC Radio Frequency Interference StatementTable of Contents Applications FeaturesAbout IE-ModeConverter DIN Rail Mounting Installing the IE-ModeConverterSFP Port Requirements Powering the IE-ModeConverter DC Terminal Block OptionCascading DC Power LED OperationDC Power Supply Precautions IMC Networks Technical SupportStandards/Compliance SpecificationsFiber Optic Cleaning Guidelines Electrostatic Discharge Precautions Safety Certifications Document Number 55-80619-00 A4