KV-HF21M80
SECTION 4
CIRCUIT ADJUSTMENTS
4-1. ADJUSTMENTS WITH COMMANDER
Service adjustments are made with the
a.ENTERING SERVICE MODE
With the unit on standby
↓
[DISPLAY]
↓
5
↓
VOL (+)
↓
[POWER]
This operation sequence puts the unit into service mode.
b.METHOD OF CANCELLATION FROM SERVICE MODE
Set the standby condition (Press [POWER] button on the commander), then press [POWER] button again, hereupon it becomes TV mode.
c. METHOD OF WRITE INTO MEMORY
1)Set to Service Mode.
2)Press [1] (UP) and [4] (DOWN), select an item of adjustment.
3)Press [MUTING] button and it will indicate WRITE on the screen.
4)Press [0] button to write into memory.
d. MEMORY WRITE CONFIRMATION METHOD
1)After adjustment, pull out the plug from AC outlet, and then plug into AC outlet again.
2)Turn the power switch ON and set to Service Mode.
3)Call the adjusted items again to confirm adjustments were made.
1, 4 Select the adjustment item.
↓
3, 6 Raise/lower the data value.
↓
[MUTING] | Writes. |
↓ |
|
-Executes the writing.
7, - All the data becomes the values in memory. 8, - All user control goes to the standard state.
5, - Service data initialization (Be sure not to use usually.)
2, - Write 50Hz adjustment data to 60Hz, or vice versa.
1 2 3
4 5 6
7 8 9
÷0 JUMP
SOUND Á PROGR
MODE
The screen display is :
FAVORITE
Device Name | Item Name | Marking of virgin NVM |
Item No
Data
Mode
TV
GEO | 00 | HPS | 1C | p | SERVICE 50 |
|
| PAL, SECAM : 50 | ||||
|
| |||||||||||
616S | 1.0C | 59 | 7F | 0 | 000A |
| NTSC | : 60 | ||||
or |
|
|
|
|
|
|
|
|
|
|
| |
623S |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
Suffix No |
|
|
|
|
|
|
|
|
|
|
| |
(OEM Code) |
|
| Total |
|
|
| ||||||
| Software | version |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
– 26 –