Panasonic TH-42PH12U PC Input Terminals connection, Signal Names for Mini D-sub 15P Connector

Page 10

Connections

PC Input Terminals connection

COMPUTER

Conversion adapter (if necessary)

(Female)

AUDIO

PC IN

Mini D-sub 15p

RGB

PC cable

(Male)

Audio

Stereo plug

Connect a cable which matches

the audio output terminal on the computer.

Notes:

Computer signals which can be input are those with a horizontal scanning frequency of 15 to 110 kHz and vertical scanning frequency of 48 to 120 Hz. (However, the image will not be displayed properly if the signals exceed 1,200 lines.)

The display resolution is a maximum of 768 × 768 dots (TH-42PH12U/L), 1,024 × 768 dots (TH-50PH12U/L) when the aspect mode is set to “4:3”, and 1,024 × 768 dots (TH-42PH12U/L), 1,366 × 768 dots (TH-50PH12U/L) when the aspect mode is set to “FULL”. If the display resolution exceeds these maximums, it may not be possible to show fine detail with sufficient clarity.

The PC input terminals are DDC2B-compatible. If the computer being connected is not DDC2B-compatible, you will need to make setting changes to the computer at the time of connection.

Some PC models cannot be connected to the set.

There is no need to use an adapter for computers with DOS/V compatible Mini D-sub 15P terminal.

The computer shown in the illustration is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

Do not set the horizontal and vertical scanning frequencies for PC signals which are above or below the specified frequency range.

Component Input is possible with the pin 1, 2, 3 of the Mini D-sub 15P Connector.

Change the “COMPONENT/RGB-IN SELECT” setting in the “SET UP” menu to “COMPONENT” (when COMPONENT signal connection) or “RGB” (when RGB signal connection).

Signal Names for Mini D-sub 15P Connector

5 4 3 2 1

10

9

 

8

7

6

15

14

 

13

12

 

11

Pin Layout for PC Input Terminal

Pin No.

Signal Name

Pin No.

Signal Name

Pin No.

Signal Name

1

R (PR/CR)

6

GND (Ground)

11

NC (not connected)

2

G (Y)

7

GND (Ground)

12

SDA

3

B (PB/CB)

8

GND (Ground)

13

HD/SYNC

4

NC (not connected)

9

+5 V DC

14

VD

5

GND (Ground)

10

GND (Ground)

15

SCL

10

Image 10
Contents Operating Instructions Manual de instrucciones English EspañolRisk of Electric Shock Do not Open Important Safety Instructions FCC Statement Trademark CreditsSafety Precautions When using the Plasma DisplaySetup MaintenanceSafety Precautions / Maintenance AC Power Supply CordAccessories Supplied AccessoriesRemote Control Batteries AC cord fixing ConnectionsFor TH-42PH12U, TH-50PH12U Cable fixing bandConnections For TH-42PH12L, TH-50PH12LSignal Names for Mini D-sub 15P Connector PC Input Terminals connectionSerial Terminals connection Signal names for D-sub 9P connectorCommand Communication parametersVideo VCR Hdmi connection for TH-42PH12U, TH-50PH12UAV connection for TH-42PH12L, TH-50PH12L CamcorderDVD Component / RGB connectionRCA-BNC DTV-STBConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet When first switching on the unit Power on / OFFOSD Language Present Time Setup Display Orientation Selecting the input signal INPUT1 INPUT2A INPUT2B INPUT3 PCInput button Input signal selection Remote control sensor Volume AdjustmentMain Power On / Off Switch Power Indicator Basic ControlsBasic Controls On-Screen Menu Displays Power Consumption SpecificationsSpecifications NTSC, PAL, PAL60, SECAM, Modified NtscPanasonic Professional Flat Panel Display Limited Warranty For the U.S.A and Puerto RicoLimited Warranty Statement For CanadaPage Page Executive Office Customer’s RecordPanasonic Professional Display Company Panasonic Canada Inc