Installation to Solid Concrete or Cinder Block
WARNING
•When installing Westinghouse wall mounts on cinder block, verify that you have a minimum of
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
1 | Use wall plate (AA), making sure that it is level, as |
a template to mark holes. Drill four 1/4" (6 mm) dia. |
holes to a minimum depth of
WARNING
•Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
•Always attach concrete expansion anchors directly to
•Never attach concrete expansion anchors to con- crete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.
1 | concrete |
| |
| surface |
|
|
EE
Drill holes and insert anchors (EE).
2 | AA |
|
CC EE
Place plate (AA) over anchors (EE) and secure with screws (CC).
3
Tighten all fasteners.
AA EE
|
| INCORRECT |
VIEW | wall | concrete |
plate |
| |
|
| |
CUTAWAY |
| plaster/ |
| dry wall | |
|
|
CORRECTCC
wall plate | concrete |
| plaster/ |
| drywall |
6 of 8 | ISSUED: |
Visit the Westinghouse Web Site at www.westinghousedigital.com | For customer service call |