JVC AV-24F704, AV 14F704 Lightning, Power Lines, Overloading, Object and Liquid Entry, Servicing

Page 3

13.LIGHTNING

To protect your unit during a lightning storm, or when it is left unattended and unused for long periods of time, unplug it from the wall outlet and disconnect the antenna or cable system. This will prevent damage to the unit due to lightning and power line surges.

14.POWER LINES

An outside antenna system should not be located in the vicinity of overhead power lines or other electric light or power circuits, or where it can fall into such power lines or circuits. When installing an outside antenna system, extreme care should be taken to keep from touching such power lines or circuits, as contact with them might be fatal.

15.OVERLOADING

Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock.

16.OBJECT AND LIQUID ENTRY

Do not push objects through any openings in this unit, as they may touch dangerous voltage points or short out parts that could result in fire or electric shock. Never spill or spray any type of liquid into the unit.

17.OUTDOOR ANTENNA GROUNDING

If an outside antenna or cable system is connected to the unit, be sure the antenna or cable system is grounded to provide some protection against voltage surges and built-up static charges, Section 810 of the National Electrical Code, ANSI/NFPA 70, provides information with respect to proper grounding of the mast and supporting structure, grounding of the lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge unit, connection to grounding elec- trodes, and requirements for the grounding electrode.

18.SERVICING

Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

19.DAMAGE REQUIRING SERVICE

Unplug this unit from the wall outlet and refer servicing to qualified service personnel under the following conditions:

a.When the power-supply cord or plug is damaged.

b.If liquid has been spilled, or objects have fallen into the unit.

c . If the unit has been exposed to rain or water.

d.If the unit does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the unit to its normal operation.

e.If the unit has been dropped or the cabinet has been damaged.

f . When the unit exhibits a distinct change in performance, this indicates a need for service.

20.REPLACEMENT PARTS

When replacement parts are required, be sure the service technician uses replacement parts specified by the manufacturer or those that have the same characteristics as the original part.

Unauthorized substitutions may result in fire, electric shock or other hazards.

21.SAFETY CHECK

Upon completion of any service or repairs to this unit, ask the service technician to perform safety checks to determine that the unit is in proper operating condition.

22.HEAT

The product should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including amplifiers) that produce heat.

23.NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV system installer's attention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practical.

EXAMPLE OF ANTENNA GROUNDING AS PER THE NATIONAL ELECTRICAL CODE

GROUND CLAMP

ELECTRIC

SERVICE

EQUIPMENT

NEC-NATIONAL ELECTRICAL CODE

S2898A

ANTENNA LEAD IN WIRE

ANTENNA DISCHARGE UNIT (NEC

SECTION 810-20)

GROUNDING CONDUCTORS (NEC SECTION 810-21)

GROUND CLAMPS

POWER SERVICE GROUNDING ELECTRODE

SYSTEM (NEC ART 250, PART H)

3

Image 3
Contents Serial Number Important Note to the CustomerPOWER-CORD Protection CleaningAccessories Power SourceSafety Check Power LinesDamage Requiring Service Replacement PartsFeatures Table of ContentsBack AC Power Cord Connect to a 120V, 60Hz outletLocation of Controls FrontBattery Installation Remote ControlRemote Control Basics Battery PrecautionsChanging the Batteries Press Return to exit Setting the CATV, VCR and DVD CodesCable Box or Satellite setup Remote ProgrammingVCR Search Codes Function VCR setupDVD Player Search Codes Function DVD setupFor Subscribers to Basic Cable TV Service ANTENNA/CATV ConnectionsSeparate VHF/UHF Antennas Component Video Connection to Other EquipmentTV/AV Selection VideoSetting Language Setting ClockPress the CH + or CH button to set the minute To ADD/DELETE Channels To Memorize ChannelsAutomatic Channel Memory TV/CATV SelectionCH Label Setting V-CHIPTV Rating Movie Rating Can ENG Rating Can FRE RatingVOL + TV Basic Operation Number of green bar also decreasesSee to Memorize Channels Stereo and Separate Audio Program SAP MONO+SAP BroadcastingSTEREO+SAP Broadcasting Sound Adjustments Picture AdjustmentsWhat is Closed CAPTIONING? Closed CaptionTo View Closed Captions ON/OFF Timer On Timer SettingOFF Timer Setting Sleep Timer button Symptoms Possible Solutions Troubleshooting GuideSpecifications AccessoriesAV-24F704 AV-20F704 AV-14F704