The fuse is located inside this compartment. Remove using a flat head screwdriver.

3.SETUP

AC Power

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture’s requirement. Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use.

Fuse Replacement

Unplug the IEC power cable before replacing the fuse! Always replace with same type of fuse.

This product has a replaceable fuse. In the event that the fuse needs to be replaced, follow the instructions provided below.

1.Using a flat head screwdriver, remove the fuseholder from the IEC housing.

2.Remove the bad fuse from the fuseholder.

3.Insert the new fuse into the fuseholder.

4. Install the fuseholder in the IEC housing.

Hurricane™ 1300 User Manual

7

August 2011

Image 7
Contents Page Table of Contents Product at a Glance What Is IncludedBefore YOU Begin Unpacking InstructionsSafety Instructions Product Overview IntroductionProduct Dimensions AC Power SetupFuse Replacement Orientation MountingOperating Instructions Timer Remote Operation FC-T StandardManual Remote Operation FC-M Optional Mode Dipswitches Wireless Controller FC-W OptionalContact Information General TroubleshootingAppendix General MaintenanceReturns Procedure Power Technical Specifications