PVM SETUP
Auto Power ON: Select the video input to be activated when power is restored after an electrical failure. Select OFF, VIDEO 1, VIDEO 2, CAMERA, or MEDIA.
Light Sensor Mode: Automatically turns on or off the monitor based on the light intensity.
L. Sensor Sensitivity: Sets the light intensity at which the monitor is turned off and on (1 to 100). The 100 setting is the more sensitive.
Light Sensor Delay: Sets the time that the Auto Day/Night feature pauses before being activated (5 to 30 seconds).
Video Loss Sleep: This is an ON/OFF function. ON sets the function that puts the monitor in sleep mode after video has been lost for
30 seconds. When a signal is detected, the monitor turns on again. To restore power immediately, use the power button on the remote control or the power button on the side of the PVM cabinet.
PIR Mode: Sets the motion detection mode: OFF, FULL, PIP, or PBP. This determines the length of time a selected video source triggered by motion detection displays on the screen (5 to 20 seconds).
PIR Sensitivity: Sets the motion detection sensitivity: LOW, MIDDLE, and HIGH. The typical detection for LOW is 16.4 to 23.0 feet (5 to 7 m); for MIDDLE, 26.2 to 32.8 feet (8 to 10 m); and for HIGH, 32.8 to 45.9 feet (10 to 14 m).
PIR Input: Sets the video input that displays when motion is detected. Select VIDEO 1, VIDEO 2, or CAMERA.
PIR Dwell: Sets the length of time a selected video source triggered by motion detection displays on the screen (5 to 20 seconds).
CYCLE SETUP
Cycle: Sets the cycle of the input source: OFF, FULL, PIP, or PBP. The settings OFF and FULL are only available if PIR Mode is set to PIP or PBP.
Video1 Cycle Time: Sets the cycle time of Video 1 (OFF, 5 to 30 seconds).
Video2 Cycle Time: Sets the cycle time of Video 2 (OFF, 5 to 30 seconds).
Camera Cycle Time: Sets the cycle time of Camera (OFF, 5 to 30 seconds).
Media Cycle Time: Sets the cycle time of Media (OFF, 5 to 30 seconds). When this feature is set to OFF, the cycle will skip the input.
CAMERA
This menu appears when there is camera input.
SYSTEM: Select NTSC or PAL.
ASPECT: Select 4:3 or 16:9.
SCAN: Select Progressive or Interlace mode.
MIRROR: Sets the camera image to be flipped horizontally (ON or OFF).
MAINTENANCE
ISM: Image sticking minimization (ISM) reduces “sticking” or retention of an image that displays for a long period of time.
If selected, the ISM function starts 10 minutes after the PVM enters “sleep mode” through the light sensor setting.
NOTE: The panel backlight is not lit during this operation.
The operation period can be set from 1 to 8 hours.
Once the function begins, wait for the period you selected to end before normal operation resumes. If necessary, you can end the ISM function by returning the environment light back to normal intensity, which “wakes up” the PVM. A second method would be to cycle power to the unit using the remote control, the power button on the side of the unit, or the power source.
Default: Select Default to return to the default settings (refer to Figure 8 on page 13); default settings are boldface.