Emerson EWD2003 owner manual Recording Function, Timer Recording, Normal Recording

Page 19
Record safety tab

RECORDING FUNCTION

VCR

It may be UNLAWFUL to record copyrighted materi- al without the consent of the copyright owner.

Accidental Erasure Prevention

To prevent accidental recording on a recorded cassette, remove its record safety tab. To record on it later, cover the hole with cellophane tape.

Before recording, make sure:

¡The desired channel is selected by pressing Number on the remote control or CHANNEL (o/p). (If you connected the VCR to a cable box or satellite box as in "DVD/VCR TO TV CONNECTION" on page 13, select channel 3 on your TV. Then, select the chan- nel you want to record with the cable box or satellite box. In this case, you can ONLY record and view the SAME channel.)

¡If noise appears, change the RF output channel of the VCR to channel 4 by pressing PLAY for 3 sec- onds during playback. Then select the same channel (CH4) on your TV.

¡There is a tape with a safety tab in the VCR.

¡The desired recording speed is selected in SP (stan- dard play) or SLP (super long play) mode by press- ing SPEED on the remote control.

¡TV STEREO or SAP is selected.

 

Tape Speed

 

Recording/Playback Time

 

Type of tape

T60

 

T120

T160

 

SP mode

1 hour

 

2 hours

2-2/3 hours

 

SLP mode

3 hours

 

6 hours

8 hours

¡If a tape ends during OTR, the VCR will stop, eject the tape, and switch to the DVD mode automatical- ly as the TIMER light blinks. (If the DVD power is off, the VCR will become STANDBY status).

¡When OTR is finished , the VCR turns off automat- ically. To use the VCR again, press T-SET on the remote, or STOP/EJECT on the DVD/VCR COM-

BINATION UNITS.

TIMER RECORDING

VCR

You may set the VCR to start recording while you are away. You can set eight programs to record on specif- ic days, daily or weekly within 1 year period.

If you have not yet set the clock, "CLOCK SET" appears. If so, follow the steps [3] and [4] in "CLOCK SET UP" section on page 17. Then, set the timer recording.

1Insert a tape with its safety tab into the

DVD/VCR COMBINATION UNITS.

2Select main menu by pressing MENU.

3 Select "TIMER PROGRAM-

TIMER PROGRAMMING

PROG

12345678

MING" by pressing K or L.

DATE

-

Then, press B. The set up

START TIME

CHANNEL

 

END

TIME

screen is displayed.

REC SPEED

 

NORMAL RECORDING

VCR

1Begin the recording by pressing RECORD. The REC Light comes on.

4Set the timer.

¡To go back one step, press s.

¡To temporarily stop recording or to resume it, press PAUSE. After the VCR has been in Pause mode for 5 minutes, it will stop automatically to protect the tape and the video head from damage.

2 Press STOP when the recording is completed.

Note

¡When you wish to watch another program while

recording, select desired channel on your TV. If

1) Set the program number (1-8)

PROGRAM NUMBER

4

 

DATE

- - / - -

 

Program number which is not set up

START TIME - - : - -

- -

END TIME - - : - -

- -

flashes. Press K or L repeatedly

CHANNEL

- -

 

REC SPEED

- -

 

 

 

 

for the desired program number. Then, press B.

2) Set the frequency of the recording

noise appears press VCR/TV.

OTR (One Touch Recording)

VCR

This feature allows you to set the recording length sim- ply by pressing REC on the VCR.

3Press REC to begin OTR. The TIMER light comes on. Change the recording length by pressing REC repeatedly.

REC

OTR(0:30)

OTR(1:00)

(Normal recording)

 

 

OTR(8:00)

 

OTR(7:30)

For once: Press K or L to point to "ONCE".

For daily (Monday~Friday): Press K or L to point to "DAILY".

For weekly: Press K or L to point to "WEEKLY".

Then, press B.

3) Set the date

First, press K or L for the month. Then, press B. Next, press K or

Lfor the day. Then, press B.

PROGRAM NUMBER 4

ONCE

DAILY WEEKLY

ONE TIME PROGRAM

PROGRAM NUMBER 4

DATE - - / - - START TIME - - : - - - -

END TIME - - : - - - -

CHANNEL - -

REC SPEED - -

– 19 –

EN

1L25

Image 19
Contents EWD2003 Laser Safety Important Safeguards Symbols Used in this Manual Supplied AccessoriesAbout Copyright Indice Table of ContentsPrecautions FeaturesExample About the DiscsPlayable Discs Following discs cannot be played back on thisOperating Controls and Functions +10 Use to select VCR or TV position Bers during channel presetPress to accept a setting Press to select VCR mode for the remote controlConnect your antenna, Cable Box, or Direct Broadcast System Loading the BatteriesSwitching to DVD Mode VCR/DVD SwitchingIf your TV does not have A/V terminals Connecting to a TVHookups DVD/VCR to TV ConnectionFor TVs with S-VIDEO Input Jack Connecting to AN Analog Audio Connecting to a Dolby Digital DecoderTo Select a Desired Channel SetupAutomatic Channel SET UP To Preset the Channels AgainTo Change the ON-SCREEN Language Clock SET UPTo ADD/DELETE Channels Search Functions Playback FunctionNormal Playback Auto Repeat PlaybackAccidental Erasure Prevention Timer RecordingRecording Function Normal Recording¡You can use the DVD player while the Timer light Hints for Timer RecordingTo Stop AN Automatic Timer PRO- Gram Already Started To CHECK, CORRECT, or Cancel AN Automatic Timer ProgramReal Time Tape Counter Special FeaturesCopying a Video Tape Auto RewindPause General FeaturesPlaying a Disc Basic PlaybackFast FORWARD/REVERSE Search Disc MenuTitle Menu Step by Step PlaybackTime Search ZoomTitle / Chapter Search TrackRepeat RepeatRepeat Title / Chapter Repeat TrackTrack Selection Random PlaybackMP3 Playback ON-SCREEN InformationAudio Language Stereo Sound ModeSubtitle Language Program¡The elapsed and remaining Playing time of the current Changing the ON-SCREEN DisplayParental Control Parental LevelWhen playing disc with copyright Protection DVD SetupMarker Setup Screen Audio SettingVirtual Surround Black Level SettingDisplay Setting ¡Be sure to press SETUP, or the setting will not workLanguage Setting Problem Corrective Action Troubleshooting GuideMake your contribution to the environment MaintenanceSpecifications Panel Delantero Controles DEL Funcionamiento Y SUS FuncionesBotón Play DVD Botón g Modo DVD NotasCambio AL Modo VCR Cambio DE VCR/DVDPreparación Conexiones¡Para retroceder un paso, presione Reproducción DE UN DiscoPreparación DE Reloj Reproduciendo UN DVD Video O UN CD AudioMemo Memo Memo 0VMN03884 TelH94 20UD

EWD2003 specifications

The Emerson EWD2003 is a cutting-edge temperature control device designed to enhance monitoring and management in industrial environments. Known for its reliability and precision, this device is utilized in a variety of applications, including HVAC systems, food processing, and environmental monitoring.

One of the standout features of the Emerson EWD2003 is its robust temperature sensing capabilities. It employs advanced sensor technology, which ensures accurate readings and responsiveness to temperature fluctuations. The device can accommodate various sensor types, such as thermocouples and RTDs, making it versatile and adaptable to differing setups.

The EWD2003 supports a broad temperature range, making it suitable for both low and high-temperature environments. Its digital display provides real-time data, allowing users to monitor conditions at a glance. Additionally, the device includes built-in alarm functionalities that alert users to any temperature deviations beyond preset thresholds, ensuring proactive management of potential issues.

Connectivity is another significant technology feature of the Emerson EWD2003. With options for both wired and wireless communications, the device can seamlessly integrate into existing monitoring systems. It supports protocols like Modbus, making it compatible with various industrial automation systems. This connectivity enhances data logging, enabling users to track historical trends and make informed decisions based on empirical data.

The EWD2003 also emphasizes user-friendliness. Its intuitive interface simplifies setup and configuration, reducing installation time. The device can be tailored to fit specific user needs, with programmable settings that allow for customization based on the requirements of the application.

In terms of characteristics, the Emerson EWD2003 is constructed for durability. Its robust design ensures it can withstand harsh industrial environments, while the quality components contribute to a longer lifespan. The device operates with energy efficiency in mind, reducing operational costs for businesses.

In conclusion, the Emerson EWD2003 stands out in the market for temperature control solutions. Its combination of accurate sensing, extensive connectivity options, user-friendly interface, and robust design makes it an ideal choice for industries that require precise temperature management. Whether for critical process monitoring or routine temperature checks, the EWD2003 is engineered to meet the demands of modern industrial applications.