Installation to Wood Stud Wall

WARNING

Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended.

Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Install- ers are responsible to provide hardware for other types of mounting situations.

1

In-wall box (A) must be installed between two studs 16" on

 

 

center. Use an edge-to-edge stud finder to locate the edges

 

 

 

of the stud. Based on its edges, draw two vertical lines down

 

STUD

 

the inside edges of stud’s. Mark desired center of in-wall box.

 

 

 

Draw a horizontal line 6-1/8" (150 mm) above center of in-wall

 

14.5"

 

box (A). Draw a second horizontal line 12-1/4" (311 mm) below

cut

(368mm)

 

this line to outline wall opening between inside edges of studs.

 

 

outline

 

 

Remove drywall inside cut outline.

 

6-1/8"

 

NOTE: In-wall box (A) can be installed for left or right side

 

 

 

(150mm)

 

mount orientation as shown in figure 1.2.

 

12-1/4"

 

Insert in-wall box (A) into cut-out until flange is flush with

 

(311mm)

 

center of

 

 

drywall.

in-wall box

 

 

Level in-wall box (A), and mark the position of two mounting

 

 

 

holes using holes on mounting tabs. Remove in-wall box (A)

 

 

 

and drill 1/8" (3 mm) dia. holes 1-1/2" (38 mm) deep using

 

 

 

the locations previously marked. Reinstall and level in-wall

 

 

 

box (A). Secure using two #10 X 1-1/2" wood screws (B) as

 

 

 

shown in figure 1.3.

 

 

Attach two mounting cover plates (C) to in-wall box (A) using

fig. 1.1

four ribbed rivets (D) as shown in figure 1.4.

 

 

A

 

 

A

A

 

 

 

 

 

 

MOUNTING

 

 

 

 

TABS

 

flange

flange

 

 

 

 

 

 

 

LEFT

RIGHT

B

C D

 

ORIENTATION

ORIENTATION

 

fig. 1.2

 

fig. 1.3

fig. 1.4

 

 

4 of 6

 

ISSUED: 12-04-07 SHEET #: 095-9280-3

03-25-10

Visit the Peerless Web Site at www.peerlessmounts.com

For customer care call 1-800-865-2112 or 708-865-8870.

Image 4
Contents Models IM740P, IM740P-S Maximum UL Load CapacityTools Needed for Assembly Table of ContentsParts List PA740, PA740P-S articulating armInstallation to Wood Stud Wall Box A. Draw a second horizontal line 12-1/4 311 mm belowRemove drywall inside cut outline Mount orientation as shown in figureInstalling Articulating Arm to In-wall Box Installing Screen to ArmAccess Cable ManagementPlate Cables Screen not shown for clarity