Seiko Instruments G1216B1N000-3D0E Function, Detailed explanation Display ON/OFF Code, D/I

Page 20

AN.No.G1216B1N000-3D0E

3.4Instructions

3.4.1General

Instructions are listed on Table 2. Instructions other than the Status Read instruction will not be executed if they are sent while another instruction is already being executed. The busy flag is “1” when executing the instruction. Check whether or not the flag is “1” before transmitting the instructions from the MPU.

 

 

 

 

 

 

 

 

 

 

 

Table 2

List of Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction

 

 

 

 

 

 

 

 

 

Code

 

 

 

 

 

 

 

 

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

 

D / I

DB7

DB6

DB5

DB4

 

DB3

DB2

DB1

DB0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turns ON / OFF total display. Data and

1

Display

0

 

0

0

 

0

 

1

 

 

1

 

 

1

 

1

1

1/0

 

internal status in the display RAM remain

 

 

 

 

 

 

 

 

 

 

unchanged.

 

 

 

ON / OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1: ON

0 : OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display start

 

 

 

 

 

 

 

 

 

 

 

 

Display start lines

 

 

Determines the RAM line to be displayed on the

2

0

 

0

1

 

1

 

 

 

 

 

 

top line (COM1) on the display.

line

 

 

 

 

 

 

 

 

 

( 0 to 63 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-address(page)

 

Sets the X-address of the RAM (page) in the

3

(page) set

0

 

0

1

 

0

 

1

 

 

1

 

 

1

 

 

(0 to 7)

 

 

X-address (page) register.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y-address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y-address

 

 

 

Set Y-address of

the RAM in the Y-address

4

0

 

0

0

 

1

 

 

 

 

 

 

 

 

 

 

counter.

 

 

 

 

set

 

 

 

 

 

 

 

 

 

( 0 to 63 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

Reads the status.

 

 

 

 

 

 

 

 

B

 

 

 

ON

 

 

 

 

 

 

 

RESET

1: Reset 0: Normal

 

Status read

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

5

1

 

0

U

 

0

 

/

 

 

S

 

0

 

0

0

0

 

ON/OFF

1: Display OFF

0: Display ON

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

E

 

 

 

 

 

 

 

BUSY

1: during internal operation

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

0: READY status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Writes data DB0 (LSB) to

Accesses the

 

Display data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB7 (MSB ) on the data

RAM in which

6

0

 

1

 

 

 

 

 

 

 

 

Write Data

 

 

 

 

bus into the display RAM.

address has been

write

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specified

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

beforehand. After

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

that the Y-address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reads data DB0 (LSB) to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

advances by one.

 

Display data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB7 (MSB) from the

 

7

1

 

1

 

 

 

 

 

 

 

 

Read Data

 

 

 

 

display RAM into the data

 

read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

bus.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The BUSY time varies depending upon the frequency F￿(:215 kHz (typ.) ) of ￿1, ￿2 (1/F

TBUSY

3/F ).

 

3.4.2 Detailed explanation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) Display ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

 

 

 

R/W D/I

 

DB7

 

 

 

 

 

 

 

 

 

 

 

 

DB0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

 

0

 

 

0

 

 

1

 

1

1

1

 

1

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turns the display ON when D=1, and OFF when D=0. When the display is turned OFF by D=0, the original display appears if D is set to 1 because the display data is retained in the display data RAM.

- 17 -

Image 20
Contents USER’S Manual AN.No.G1216B1N000-3D0ECopyright 1993 by Seiko Instruments Inc Contents General +80 Temperature Storage Symbol Conditions Min Typ Max Unit Input HighPower supply voltage VoltageMin Typ Max Unit Remark 25 C Vopr=13.0 Viewing angle∅ = 25 C Vopr=13.0 Contrast 25 C Vopr=13.0AN.No.G1216B1N000-3D0E Definition of response time −20 To +70 Storage temp. rangeLeda Number of LEDChips=20 LedcDB0 DB1DB2 DB3V c, V d, V f Circuit ConfigurationCS2 CS1 CS R/W FRMMSB LSBBusy Page COM1 COM2COM3 COM4Operational Amplifier Bias R2= 9 4 R1= 5 R1 CS1 CS2 Operating InstructionsMPU 450 140To DB7 Test point RL = 2.4 k = 11 kReset time Rise time 200D/I FunctionDetailed explanation Display ON/OFF Code AN.No.G1216B1N000-3D0E Display start line Code DB7 DB0Display start line=0 Display start line=1 Display start line =2 Display start line=3Display Data RAM Address Configuration AN.No.G1216B1N000-3D0E Address page set CodeReset Voltage V opr 13.5 13.0 12.5 11.5 10.5 =10 k Ω=1.2 k Ω Variable resistor=Input voltage power voltageV =LED forward voltage=Allowable LED forward current a Leda LedcMPU Connection Diagram Z80 PIOD0 to D7 A0 to A7 DB0 to DB7 A0 to A15 Decoder Iorq RST CS1Precautions 9, 11, 12, 17, 18, 19 11, 12, 1710, 16, 17 LC drive voltageSeiko Instruments Inc