Sim2 Multimedia C3X Link specifications Be EF 03 19 00 4C 4E 01 84 08 00 00 00 00 00

Page 11

SIM2 C3X LINK

RS-232C CONTROL SPECIFICATIONS

 

SET YCrCb

BE EF 03 19 00 4C 4E 01 84 08 00 00 00 00 00 00

 

AutoSync

16

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

SET YCrCb 15kHz

BE EF 03 19 00 85 46 01 84 08 00 00 00 00 00 00

 

0A

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

INPUT 7

SET YCrCb 32kHz

BE EF 03 19 00 8F 4C 01 84 08 00 00 00 00 00 00

12

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

(COMP RGB 3) /

 

 

BE EF 03 19 00 49 4B 01 84 08 00 00 00 00 00 00

SIGNAL TYPE

SET RGB AutoSync

1A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

SET RGB 15kHz

BE EF 03 19 00 80 43 01 84 08 00 00 00 00 00 00

 

06

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

SET RGB 32kHz

BE EF 03 19 00 46 44 01 84 08 00 00 00 00 00 00

 

0E

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

SET YCrCb

BE EF 03 19 00 49 D2 01 85 08 00 00 00 00 00 00

 

AutoSync

17

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

SET YCrCb 15kHz

BE EF 03 19 00 80 DA 01 85 08 00 00 00 00 00 00

 

0B

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

INPUT 8

SET YCrCb 32kHz

BE EF 03 19 00 8A D0 01 85 08 00 00 00 00 00 00

13

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

(COMP RGB 4) /

 

 

BE EF 03 19 00 4C D7 01 85 08 00 00 00 00 00 00

SIGNAL TYPE

SET RGB AutoSync

1B 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

SET RGB 15kHz

BE EF 03 19 00 85 DF 01 85 08 00 00 00 00 00 00

 

07

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

SET RGB 32kHz

BE EF 03 19 00 43 D8 01 85 08 00 00 00 00 00 00

 

0F

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

RECALL

BE EF 03 19 00 85 EB 01 27 09 00 00 01 00 00 00

 

01

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

MEMORY 1

SAVE CURRENT

BE EF 03 19 00 54 D6 01 27 09 00 00 00 00 00 00

SETTINGS

01

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

SAVE INITIAL

BE EF 03 19 00 45 9A 01 28 09 00 00 01 00 00 00

 

SETTINGS

01

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

RECALL

BE EF 03 19 00 74 AB 01 27 09 00 00 01 00 00 00

 

02

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

MEMORY 2

SAVE CURRENT

BE EF 03 19 00 A5 96 01 27 09 00 00 00 00 00 00

SETTINGS

02

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

SAVE INITIAL

BE EF 03 19 00 76 DE 01 28 09 00 00 02 00 00 00

 

SETTINGS

01

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

RECALL

BE EF 03 19 00 E4 6A 01 27 09 00 00 01 00 00 00

 

03

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

MEMORY 3

SAVE CURRENT

BE EF 03 19 00 35 57 01 27 09 00 00 00 00 00 00

SETTINGS

03

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

SAVE INITIAL

BE EF 03 19 00 A7 E3 01 28 09 00 00 03 00 00 00

 

SETTINGS

01

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

The response of the unit to a correct Operation Code consists of the byte 1E followed by a copy of the packet that has been sent to the unit, where, however:

-byte number 11 is set at 01,

-CRC (bytes number 6 and 7) has been altered accordingly.

0

 

 

1

 

2

3

 

 

 

 

4

 

 

5

 

 

6

 

7

 

1E

 

 

BE

 

EF

Packet Type

 

 

 

Packet Payload Size

 

 

 

 

Packet Checksum (CRC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

9

10

 

 

11

 

 

12

 

13

 

14

 

15

 

 

16

 

 

 

17

18

 

19

 

Op Type

 

 

Op ID

 

 

 

01

 

 

00

 

Op Target

 

00

 

 

00

 

 

 

Value

 

 

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

00

11

Image 11
Contents Control Specifications Table of Contents Communication Parameters IntroductionConnection SIM 2 C3X Link RS-232C Control PortEvent Packet Format Communication ProtocolHeader PayloadRemote Control Keycodes CommandsRemote Control Key Codes Direct access codes Operation Codes Operation Codes Be EF 03 19 00 27 B4 01 C2 09 00 00 00 00 00 Be EF 03 19 00 0E ED 01 C2 09 00 00 00 00 00 Be EF 03 19 00 D8 EE 01 4A 08 00 00 00 00 00 Be EF 03 19 00 4C 4E 01 84 08 00 00 00 00 00 Get Codes Get CodesMemory Color TemperatureGamma Unit returns the code Examples