Sim2 Multimedia C3X Link specifications Get Codes

Page 12

21 22

00

00

 

 

23 24 25 26

00

00

00

00

 

 

 

 

SIM2 C3X LINK

RS-232C CONTROL SPECIFICATIONS

27 28 29 30 31 32

00

00

00

00

00

00

 

 

 

 

 

 

Get Codes

Get Commands may be used to get the current value of projector parameters.

The response to a correct Get Command consists of 33 byte packet, where Byte Number 11 contains the Validation Code (01) and bytes Number 17 and Number 18 the requested value (the least-significant byte of the value being sent first). Of course CRC (bytes number 6 and 7) has been altered accordingly.

0

 

 

1

 

2

3

 

 

 

 

4

 

 

5

 

 

6

 

7

 

1E

 

 

BE

 

EF

Packet Type

 

 

 

Packet Payload Size

 

 

 

 

Packet Checksum (CRC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

9

10

 

 

11

 

 

12

 

13

 

14

 

15

 

 

16

 

 

 

17

18

 

19

 

Op Type

 

 

Op ID

 

 

 

01

 

 

00

 

Op Target

 

00

 

 

00

 

 

 

Req Value

 

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

00

21

22

23

24

25

26

27

28

29

30

31

32

 

 

 

 

 

 

 

 

 

 

 

 

00

00

00

00

00

00

00

00

00

00

00

00

Get Codes:

 

BE EF 03 19 00 52 2A 02 00 08 00 00 00 00 00 00

(1)

BRIGHTNESS

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 C7 77 02 01 08 00 00 00 00 00 00

(1)

CONTRAST

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 38 93 02 02 08 00 00 00 00 00 00

(2)

COLOR

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 AD CE 02 03 08 00 00 00 00 00 00

(3)

TINT

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 9D 0B 02 C2 09 00 00 00 00 00 00

(4)

COLOR TEMPERATURE

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 13 25 02 27 08 00 00 00 00 00 00

(5)

GAMMA

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 5E D5 02 27 09 00 00 01 00 00 00

(6)

MEMORY

 

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Image 12
Contents Control Specifications Table of Contents Introduction ConnectionSIM 2 C3X Link RS-232C Control Port Communication ParametersCommunication Protocol HeaderPayload Event Packet FormatCommands Remote Control Key CodesRemote Control Keycodes Direct access codes Operation Codes Operation CodesBe EF 03 19 00 27 B4 01 C2 09 00 00 00 00 00 Be EF 03 19 00 0E ED 01 C2 09 00 00 00 00 00 Be EF 03 19 00 D8 EE 01 4A 08 00 00 00 00 00 Be EF 03 19 00 4C 4E 01 84 08 00 00 00 00 00 Get Codes Get CodesColor Temperature GammaMemory Examples Unit returns the code