Fluke VR101S manual Viewing the Default Threshold Settings, Choosing Operating Options

Page 23

Setting Up the VR101

Starting EventView 2

Viewing the Default Threshold Settings

The EventView program has factory-installed default threshold settings. These settings are adequate for most applications.

To see the default threshold settings on the Status tab, click the Default Setup button.

If you are concerned that some of your electronic equipment may have particular power quality requirements, we suggest that you call the equipment manufacturer for that information. You may discover that you should alter some of the recorder’s threshold settings in order to monitor power quality more closely.

Choosing and Saving New Default Threshold Settings

If the factory-installed default threshold settings of the recorder do not suit your application you may choose new settings and designate them as the default settings.

1.Make your changes to the settings.

2.Click the Save as Default Setup button.

3.In the dialog box that appears, click OK to confirm that the default settings will be changed.

These settings are now saved in your computer and can be sent to any recorder that you communicate with by clicking Send Setup/Clear Recorder.

Choosing Operating Options

Stop Recording When Full or Overwrite Oldest Events When Full

A recorder can store 4,000 events. You can program it to either stop recording events or to continue recording when it is full and record over the oldest events in its memory.

Choose either Stop Recording When Full or Overwrite Oldest Events When Full.

Flash When Data Available

Check Flash When Data Available if you want the recorder to blink when it has stored one or more events (default condition).

15

Image 23
Contents VR101S Page Limited Warranty & Limitation of Liability Service Centers Table of Contents Chapter Chapter VR101S Introduction Features of the Voltage Event Recorder SystemGetting Started Quick Overview Plugging in a recorder SafetyPolarity Indication Using an Ungrounded OutletElectrical Immunity Safety InspectionBattery Care Product Service MaintenanceWhat’s in the VR101S Package What You Need to Run Fluke EventView SoftwareInstalling EventView software Installing EventView software Setting the Time and Date Starting EventView Setting Up the VR101Connecting the Optical Interface Cable Opening the Site Report Window Selecting a COM PortVoltage Swells Setting Thresholds on the Status TabVoltage Transients Line Frequency Variations Voltage SagsChoosing Operating Options Viewing the Default Threshold SettingsChoosing and Saving New Default Threshold Settings Flash When Data AvailableViewing Recorder Information Describing the SiteViewing Realtime Readings of the Recorder Starting Event Recording Sending the Setup to the RecorderClearing all events from the recorder VR101S Retrieving Events from a Recorder Retrieving Saving EventsSaving Events Opening an Already Saved File VR101S Viewing the Events Tab Displaying and Printing EventsDisplaying Events Event column Event # columnStart Time column Displaying and Printing Events Hot to Neutral Thresholds End Time/Duration/Degree Column Extreme ColumnVR101S Viewing Events as a Bar Graph Quick Summary Viewing a Single Transient as a Graph Viewing Events as an Event Distribution Graph VR101S Changing Graph Styles Printing Events from the Events Tab Printing EventsOptical Interface Cable TroubleshootingIRQ Voltage Event Recorder PrintersTechnical Support Effects of Poor Power Quality within Your Organization Power Quality IssuesPower Quality Background Why Is It Such a Concern?Why Not Buy a Protection Device? Common Questions about Power QualityWhy Not Use a Meter and Check? Disturbance-Free Voltage Common Power Line Disturbances Power Quality Definitions StandardsPower Line Disturbance Definitions Cbema Curve How Bad is Bad?Causes of Poor Power Quality Causes and Effects of Poor Power QualityHow Power Line Disturbances Affect Your Equipment Developing a Power Quality Monitoring Program Performing a Power Quality StudyDeveloping the Study Duration Strategy Finalizing the Power Quality Monitoring PlanDeveloping a Location Plan Developing a Tolerance PlanFinal Note Unrepetitive / Isolated Events Now That I Have This Information, What Do I Do with It?Repetitive / Cycling Events Transient Power Line VR101S Equipment Ratings VR101 SpecificationsPlug Configurations VR101 Specifications Neutral to ground Sag, Swell & Outage MeasurementFrequency Measurement Transient MeasurementEvents 1 second Time MeasurementApprovals Statement of Conformity Declaration of ConformityIndex VR101S Index VR101S

VR101S specifications

The Fluke VR101S is a revolutionary tool designed for professionals in the electrical and maintenance fields, offering innovative features and technology that enhance safety and efficiency. This compact and versatile device is engineered to simplify the process of voltage verification and insulation testing, making it an indispensable addition to any toolkit.

One of the standout features of the Fluke VR101S is its ability to perform a comprehensive range of tests with a single device. It allows users to check AC and DC voltages, perform insulation resistance tests, and verify the integrity of electrical systems. This versatility eliminates the need for multiple tools, streamlining workflows and minimizing the risk of errors.

The device utilizes advanced technology to ensure accurate and reliable measurements. With a wide voltage range capable of detecting voltage levels from 0 to 600V, the VR101S can cater to various applications, whether it be in residential, commercial, or industrial settings. The automatic voltage detection feature is particularly noteworthy; it automatically identifies the presence of voltage and indicators that provide visual alerts, enhancing user safety.

Another key characteristic of the Fluke VR101S is its robust design. Built to endure the rigors of fieldwork, the device features a rugged exterior that is resistant to drops and impacts, ensuring longevity in challenging environments. Additionally, its high-contrast LCD display provides clear readings in various lighting conditions, which boosts usability and reduces the tendency for user error.

The ergonomic design of the Fluke VR101S provides users with comfort during prolonged operation. Its lightweight form factor makes it easy to carry and handle, while the intuitive interface allows for quick navigation through its functions. Users appreciate how easy it is to switch between tests, as this efficiency translates into better productivity on the job.

Its battery life is another significant advantage, with the device designed to offer extended usage on a single charge. This feature is crucial for professionals who often work in the field and can face situations where recharging may not be immediately feasible.

In conclusion, the Fluke VR101S is a powerful and efficient voltage and insulation testing tool that brings together an array of features, robust technology, and dependable performance. Its versatility, user-friendly design, and emphasis on safety make it an essential instrument for electricians and maintenance professionals seeking to enhance their operational capabilities. Whether tackling routine maintenance or critical troubleshooting tasks, the Fluke VR101S stands out as a reliable partner for any electrical work.