CHAPTER 5: Operation

5.2 RS-422/485 Circuitry

The RS-422/485 side of the Converter is made up of the driver, receiver, and line- termination networks. As described in Chapter 3, you can use switch S2 to either connect the receiver’s termination network to the line (terminate the RS-422/485 port) or leave it unconnected (unterminated).

Having the line terminated will reduce distortion and improve the overall signal quality in most applications. For point-to-point systems where only two devices are connected to the line, each device should have the termination network connected to the line. In multipoint applications, only the two devices at the extreme ends of the line should have the termination network connected to the line. If any of the other converters were configured as “terminated,” the amount of signal distortion would increase and probably cause errors in the data being transmitted. For more on the RS-422/485 connector pinning, see the Appendix.

13

Image 14
Contents RS-232↔RS-422/485 Converter Data Only European Union Declaration of Conformity RS-232↔RS-422/485 Converter Data only NOM STATEMENT, Trademarks Contents Specifications User ControlsMtbf Wire full-duplex point-to-point application IntroductionConfiguration Configuration Installation DeviceOperation RS-232 CircuitryBlock diagram of Converter functions in DCE mode RS-422/485 Circuitry Troubleshooting Calling Black BoxTable A-1. Pinning of the RS-232 connector DB25 female Appendix PinoutsTable A-2. Pinning of the RS-422/485 connector Page Page Copyright 2001. Black Box Corporation. All rights reserved