Adder Technology X100 manual Switches 2

Page 8

X100 module switches

Certain aspects of operation can be affected by the switches on the X100 module.

OFF: Normal operation

ON: Flash upgrade

ON

1

2

 

 

 

3

4

 

 

 

 

 

Determines configuration of hotkeys in conjunction with switch 3

Reserved for future use

Switch 1

OFF: Normal operation.

ON: (Before power is applied) Places the X100 module into flash upgrade mode so that the internal software can be changed. Please see the Flash upgrade section in the ‘Special configuration’ chapter.

Switches 2 and 3

contents

Determines configuration of hotkeys in conjunction with switch 2

ON 1

2

 

 

 

3

4

 

 

 

 

 

Note: When shipped, all switches are set in the OFF positions and this will produce normal operation.

Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as ‘hotkeys’. Hotkeys signal to the X100 module that the next key to be pressed is a special configuration command for the module and is not to be passed to the computer system.

2

OFF

 

3

OFF

Hotkeys = CTRL and SHIFT

2

OFF

 

3

ON

Hotkeys = ALT and SHIFT

2 ON

 

3

OFF

Hotkeys = CTRL and ALT

2 ON

 

3

ON

Hotkeys disabled

Switch 4

This switch is reserved for future use.

 special installation  configuration & welcome



Image 8
Contents Adder X100 Extender Set Contents Welcome IntroductionSupplied items Package variants Category Cable length advice Connections Connections at the CAM local unit ModuleConnections at the X100 remote module WelcomeSwitch Switches 2Locking and unlocking the system OperationGeneral use To exit from configuration mode ConfigurationTo enter and use configuration mode Password setting To set a passwordMicrosoft and Logitech -specific mouse settings Hot plugging and mouse restorationVideo compensation sharpness and brightness To apply remote user video compensationReport X100-series firmware version Miscellaneous settingsReset all configuration options to default states Performing flash upgrades Getting assistance US +1 888 275Warranty Safety informationRadio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States Canadian Department of Communications RFI statementUnited States of America